2023
DOI: 10.1016/j.ijmst.2022.12.003
|View full text |Cite
|
Sign up to set email alerts
|

Flotation separation of wolframite from calcite using a new trisiloxane surfactant as collector

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2023
2023
2025
2025

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 24 publications
(7 citation statements)
references
References 37 publications
0
7
0
Order By: Relevance
“…6. It can be presented that these two samples dropped as the pH value increases without depressant/collector, the isoelectric point of fluorite and calcite was located at approximately pH 7.5 and 9.0, separately, it was closed to the earlier investigations (Liu et al, 2021a;Liu et al, 2021;Shuai et al, 2023). In the presence of NaOl alone, both calcite and fluorite zeta potentials decreased which suggested that interaction occurred between fluorite/calcite and NaOl, this caused no selectively between fluorite and calcite (see Fig.…”
Section: Zeta Potentials Resultsmentioning
confidence: 79%
See 2 more Smart Citations
“…6. It can be presented that these two samples dropped as the pH value increases without depressant/collector, the isoelectric point of fluorite and calcite was located at approximately pH 7.5 and 9.0, separately, it was closed to the earlier investigations (Liu et al, 2021a;Liu et al, 2021;Shuai et al, 2023). In the presence of NaOl alone, both calcite and fluorite zeta potentials decreased which suggested that interaction occurred between fluorite/calcite and NaOl, this caused no selectively between fluorite and calcite (see Fig.…”
Section: Zeta Potentials Resultsmentioning
confidence: 79%
“…Regarding the calcite, Fig. 9a plotted that Ca2p3/2 and Ca 2p1/2 peaks of calcium carbonate were observed at the peaks of 346.81 eV and 350.35 eV (Liu et al, 2022, Zhou et al, 2023Zhang et al, 2023). When calcite surface was treated with PMAA, two new fitted peaks emerged at 347.58 eV and 351.10 eV (Fig.…”
Section: Xps Analysismentioning
confidence: 91%
See 1 more Smart Citation
“…scheelite and calcite [83]. This collector also exhibited good separation performance in the flotation of wolframite and calcite [84].…”
Section: Cationic Collectorsmentioning
confidence: 88%
“…The cationic collector mainly interacted with the negatively charged scheelite surface through electrostatic interactions and showed less adsorption on the positively charged calcite surface, which provided the selective separation of scheelite and calcite [83]. This collector also exhibited good separation performance in the flotation of wolframite and calcite [84].…”
Section: Cationic Collectorsmentioning
confidence: 98%