2021
DOI: 10.1016/j.electacta.2021.138074
|View full text |Cite
|
Sign up to set email alerts
|

Flow injection amperometry as an alternative to potentiometry for solid contact ion-selective membrane-based electrodes.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
4
0
1

Year Published

2022
2022
2024
2024

Publication Types

Select...
3
2

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 36 publications
0
4
0
1
Order By: Relevance
“…The current response is linearly dependent on the concentration of potassium chloride in the range from 2.5 × 10 −5 to 1 × 10 −3 M (Figure 3). As a result of coating the PB nanoparticles with the ISM, the sensitivity in Bis-Tris becomes equal to 3.6 ± 0.4 mA•M −1 •cm −2 , which is comparable to a sensor based on PEDOT(PSS) [5]. A separate solution method was used to find the selectivity coefficient logK Na + /K + = −2.7.…”
Section: Resultsmentioning
confidence: 95%
See 2 more Smart Citations
“…The current response is linearly dependent on the concentration of potassium chloride in the range from 2.5 × 10 −5 to 1 × 10 −3 M (Figure 3). As a result of coating the PB nanoparticles with the ISM, the sensitivity in Bis-Tris becomes equal to 3.6 ± 0.4 mA•M −1 •cm −2 , which is comparable to a sensor based on PEDOT(PSS) [5]. A separate solution method was used to find the selectivity coefficient logK Na + /K + = −2.7.…”
Section: Resultsmentioning
confidence: 95%
“…The peak current increases with the increase in the concentration of potassium chloride. Previously, for SC-ISEs based on conductive polymers (polyaniline, PEDOT), it was shown that the first peak is the analytical signal [4,5]. Hence, the sensor sensitivity was estimated from the plot of the cathodic current peak versus the concentration of potassium chloride.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Rigorously speaking, these data do not refer to ionophore-based membranes. However, promising results were obtained also with K +selective and Na + -selective ISEs (glassy carbon/PEDOT-PSS/PVC membrane) in flow injection amperometric measurements at a constant potential [85].…”
Section: Herementioning
confidence: 99%
“…A demanda por análises mais rápidas, precisas e de menor custo, tem levado ao desenvolvimento de processos mecanizados ou automatizados. Sistemas em fluxo, como o FIA, se constituem em um campo fértil para estes desenvolvimentos [81].…”
Section: -Técnicas Eletroquímicasunclassified