Reference Module in Chemistry, Molecular Sciences and Chemical Engineering 2018
DOI: 10.1016/b978-0-12-409547-2.14557-3
|View full text |Cite
|
Sign up to set email alerts
|

Flow Injection Analysis—Environmental and Agricultural Applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(1 citation statement)
references
References 84 publications
0
1
0
Order By: Relevance
“…Because of its ability to analyze several samples, a very quick response time, tiny sample size injection, and excellent accuracy (8) .A liquid sample must be injected into a carrier solution that is moving in a continuous to the detector that records continuously the changes in absorbance (9,10) .Low sample and reagent use, partial and repeatable development of the related processes, and other characteristics of flow analysis are inherent (11) .Phenol an aromatic organic molecule consisting of a hydroxyl functional group (-OH) .Phenolic derivative compounds widely present in the environment,are used to make dyes ,polymers,medicines,and other organic molecules.Skin absorption, inhalation, ingestion,and a number of other methods can all result in phenol poisoning.If people are exposed to high doses of phenol, they could die (12 ), Many methods have been reported in literature for estimating total phenolic compounds such as determination total phenolic compounds in tea samples by Flow injection analysis system (13) ,automatic method for the determination of Folin-Ciocalteu reducing capacity in food products (14) .Flow injection system successful and fast method after adding smart phone technology to the design .…”
Section: Introductionmentioning
confidence: 99%
“…Because of its ability to analyze several samples, a very quick response time, tiny sample size injection, and excellent accuracy (8) .A liquid sample must be injected into a carrier solution that is moving in a continuous to the detector that records continuously the changes in absorbance (9,10) .Low sample and reagent use, partial and repeatable development of the related processes, and other characteristics of flow analysis are inherent (11) .Phenol an aromatic organic molecule consisting of a hydroxyl functional group (-OH) .Phenolic derivative compounds widely present in the environment,are used to make dyes ,polymers,medicines,and other organic molecules.Skin absorption, inhalation, ingestion,and a number of other methods can all result in phenol poisoning.If people are exposed to high doses of phenol, they could die (12 ), Many methods have been reported in literature for estimating total phenolic compounds such as determination total phenolic compounds in tea samples by Flow injection analysis system (13) ,automatic method for the determination of Folin-Ciocalteu reducing capacity in food products (14) .Flow injection system successful and fast method after adding smart phone technology to the design .…”
Section: Introductionmentioning
confidence: 99%