2015
DOI: 10.1088/1742-6596/648/1/012016
|View full text |Cite
|
Sign up to set email alerts
|

Flow meter calibration by volumetric method and by weighing method using an innovative system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2018
2018
2020
2020

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 1 publication
0
2
0
Order By: Relevance
“…Testing vertical cylindrical tanks are generally divided into two parts, namely: volumetric methods and geometric methods. The volumetric method is used for vertical cylindrical tank volumes of less than 50 kl, with the standard being a standard measuring vessel and a flow meter [2] that is calibrated by the volumetric method [3]. At the same time, the geometric method is divided into two, namely: the strapping method and optical method.…”
Section: Introductionmentioning
confidence: 99%
“…Testing vertical cylindrical tanks are generally divided into two parts, namely: volumetric methods and geometric methods. The volumetric method is used for vertical cylindrical tank volumes of less than 50 kl, with the standard being a standard measuring vessel and a flow meter [2] that is calibrated by the volumetric method [3]. At the same time, the geometric method is divided into two, namely: the strapping method and optical method.…”
Section: Introductionmentioning
confidence: 99%
“…A major challenge with stock keeping is the accuracy of the calibration charts. The calibration method; whether wet or dry influences the calibration accuracy [4] , [5] , [6] . Also, the calibration procedure and the experience of the calibration team also affect the accuracy of the calibration chart data.…”
Section: Datamentioning
confidence: 99%