2023
DOI: 10.1016/j.jhazmat.2023.130822
|View full text |Cite
|
Sign up to set email alerts
|

Flumequine-mediated fluorescent zeolitic imidazolate framework functionalized by Eu3+ for sensitive and selective detection of UO22+, Ni2+ and Cu2+ in nuclear wastewater

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
5
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
9

Relationship

3
6

Authors

Journals

citations
Cited by 22 publications
(6 citation statements)
references
References 78 publications
1
5
0
Order By: Relevance
“…In order to enhance the assessment of the detection efficacy of CuMOF in sensing of 3-NT, the plot for I 0 /I of CuMOF suspensions versus 3-NT concentrations was presented in Figure 5c, and the Stern-Volumer equation of I 0 /I = 19,480[3-NT] + 0.9803 (K sv = 1.94 Â 10 4 M À1 , R 2 = 0.9808) was calculated by using data from a low concentration range. 36,38,[46][47][48][49] According to LOD = 3σ/K sv (here σ represents the standard deviation calculated for a set of 10 blank samples), the detection limits (LOD) were found 0.49 μM (110.8 ng/ml), similar to other reported ones [50][51][52] (Table 1). Besides, the time-dependent luminescence intensity of CuMOF suspensions indicated the response time as low as 25 seconds (Figure S8).…”
Section: Detectability Toward 3-nt Biomarkersupporting
confidence: 70%
“…In order to enhance the assessment of the detection efficacy of CuMOF in sensing of 3-NT, the plot for I 0 /I of CuMOF suspensions versus 3-NT concentrations was presented in Figure 5c, and the Stern-Volumer equation of I 0 /I = 19,480[3-NT] + 0.9803 (K sv = 1.94 Â 10 4 M À1 , R 2 = 0.9808) was calculated by using data from a low concentration range. 36,38,[46][47][48][49] According to LOD = 3σ/K sv (here σ represents the standard deviation calculated for a set of 10 blank samples), the detection limits (LOD) were found 0.49 μM (110.8 ng/ml), similar to other reported ones [50][51][52] (Table 1). Besides, the time-dependent luminescence intensity of CuMOF suspensions indicated the response time as low as 25 seconds (Figure S8).…”
Section: Detectability Toward 3-nt Biomarkersupporting
confidence: 70%
“…The GGA-PBE functional and DNP4.4 basis sets were used for the calculations. In the current study, the convergence criterion of the electronic self-consistent field (SCF) loop was set to be 10 –6 with energy 10 –5 Ha, force constant 0.002 Ha/Å, displacement 0.005 Å, and value of smearing 0.05 Ha 27 , 28 . Considering that the metal ions might interact with the carboxyl groups in the organic ligands, H 2 BPDC and RhB, to simplify the computational process, the optimized structure considered only a single carboxyl group and a metal ion on the ligand.…”
Section: Methodsmentioning
confidence: 99%
“…Moreover, the inevitable sample pretreatment prior to instrumental analysis, such as filtration and digestion, also imparts threats on the operators’ health, owing to the possible radioactivity of the samples. On the other hand, photoluminescent detection methods have received considerable attention for the analysis of UO 2 2+ owing to the opration simplicity and safety, and the low cost as well. , Among them, lanthanide metal–organic frameworks (Ln-MOFs) with adjustable ordered porous structures for introducing abundant binding sites, as well as large Stokes shifts for avoiding spectral cross-talk, offered invaluable opportunities for constructing fluorescence probes for UO 2 2+ . , …”
Section: Introductionmentioning
confidence: 99%