2014
DOI: 10.1039/c4ay00987h
|View full text |Cite
|
Sign up to set email alerts
|

Fluorescence polarization immunoassay for highly efficient detection of clothianidin in agricultural samples

Abstract: A homogeneous fluorescence polarization immunoassay (FPIA) based on a monoclonal antibody was successfully developed and applied in the determination of clothianidin in agricultural samples. Three fluorescein-labeled clothianidin tracers containing different bridge lengths (2-, 4-and 6-carbon bridges) were synthesized and employed to investigate the effect of tracer structures on the FPIA. Under optimal conditions, the fluoresceinthiocarbamyl hexamethylenediamine-labeled clothianidin conjugate (HMDFlabeled clo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
10
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 18 publications
(10 citation statements)
references
References 25 publications
0
10
0
Order By: Relevance
“…It seems that the high CR from ciprofloxacin is usually inevitable in the immunoassay of FQ drugs, but a statutory confirmatory method is usually still needed to exclude the false positive after a screening assay . For a rapid screening purpose, the FPIA with low CR is acceptable considering the speed and convenience of an FPIA …”
Section: Resultsmentioning
confidence: 99%
“…It seems that the high CR from ciprofloxacin is usually inevitable in the immunoassay of FQ drugs, but a statutory confirmatory method is usually still needed to exclude the false positive after a screening assay . For a rapid screening purpose, the FPIA with low CR is acceptable considering the speed and convenience of an FPIA …”
Section: Resultsmentioning
confidence: 99%
“…Thus, the conclusion from previous publications that the longer the spacer, the higher the sensitivity, can be conrmed. 27,[32][33][34] For CBZ-triglycine-AAF, the optimum dynamic range was reached, even by using only half of the antibody amount that had to be used for CBZ-triglycine-EDF. This can be explained by the previously shown high affinity of the antibody towards CBZtriglycine-AAF.…”
Section: Optimization and Comparison Of Fpia Using Different Tracersmentioning
confidence: 99%
“…This assay has been applied to food, diagnostic and environmental analysis to determine small compounds, including mycotoxins, drugs and pesticides. [27][28][29][30][31][32][33][34][35][36][37][38] The principle of FPIA is based on the polarization difference between an unbound and an antibody-bound uorophorelabeled analyte (tracer). The analyte and the tracer compete for the analyte-specic binding sites of the antibody.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Furthermore, due to the one-step detection and ratiometric technique, the FP value is less prone to interference from operational errors and inner-lter effects so that the result is stable and shows good reproducibility. [18][19][20] Besides, the development of portable uorescence polarization detector makes FPIA more potential in pesticide residue detection. [21][22][23] In this work, we prepared an anti-thiacloprid mAb (mAb, C9) with high sensitivity, and labeled thiacloprid hapten with uorescein isothiocyanate (FITC) to develop FPIA for detection of thiacloprid.…”
Section: Introductionmentioning
confidence: 99%