Abstract:Magneto-Rheological (MR) fluids having the magnetic field dependent viscosity is responsible for the variable damping coefficient of MR dampers. The energy dissipated by the MR damper has a direct influence of the total magnetic flux density in the fluid flow gap. The total magnetic flux density is a function of geometric, material property and operating condition. In this paper, the flux deviating technique in the form of diamagnetictic coating is incorporated in the damper to enhance the total magnetic flux … Show more
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.