2019
DOI: 10.1109/access.2019.2908866
|View full text |Cite
|
Sign up to set email alerts
|

Foreign Object Detection in a Wireless Power Transfer System Using Symmetrical Coil Sets

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
42
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
3
2
2

Relationship

0
7

Authors

Journals

citations
Cited by 88 publications
(42 citation statements)
references
References 20 publications
0
42
0
Order By: Relevance
“…The detection method based on a passive induced voltage deviation focuses on the electromagnetic coupling effect of the metal object, where the change in the EMF causes an induced voltage deviation of the additional detection coil [58][59][60][85][86][87][88][89][90][91][92] or the tunable magnetoresistive (TMR) sensor [57]. The equivalent circuit is shown in Figure 10.…”
Section: (C) Detection Methods Based On a Passive Induced Voltage Devimentioning
confidence: 99%
See 3 more Smart Citations
“…The detection method based on a passive induced voltage deviation focuses on the electromagnetic coupling effect of the metal object, where the change in the EMF causes an induced voltage deviation of the additional detection coil [58][59][60][85][86][87][88][89][90][91][92] or the tunable magnetoresistive (TMR) sensor [57]. The equivalent circuit is shown in Figure 10.…”
Section: (C) Detection Methods Based On a Passive Induced Voltage Devimentioning
confidence: 99%
“…The equivalent circuit is shown in Figure 10. In [58][59][60][85][86][87][88][89][90][91][92], the induced voltage deviation of the additional detection coil was always utilized to verify the distorted EMF between the transmission coils in the presence of metal objects. The detection coil was always located on the transmitting pad and contained two reverse direction or symmetric direction coil loops to cancel the induced voltage generated by the transmitting coil.…”
Section: (C) Detection Methods Based On a Passive Induced Voltage Devimentioning
confidence: 99%
See 2 more Smart Citations
“…The other type of FOD method applies active or passive auxiliary coil sets. The passive coil sets (PCS) measure the induced voltage caused by the magnetic field produced by the eddy current within the MFO [7]- [9]. Thus, this approach requires excitation of the transmitter and zero couplings between the transmitter and the detection coil sets.…”
Section: Introductionmentioning
confidence: 99%