2017
DOI: 10.1016/j.ijms.2017.10.005
|View full text |Cite
|
Sign up to set email alerts
|

Fractionation in the graphitization reaction for 14 C-AMS analysis: The role of Zn × the role of TiH 2

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
6
0
1

Year Published

2018
2018
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 8 publications
(7 citation statements)
references
References 22 publications
0
6
0
1
Order By: Relevance
“…CO 2 samples were then transferred to 9 mm Pyrex tubes previously prepared with titanium hydride and zinc on the bottom and iron powder inside a 6-mm inner tube. Tubes were sealed with an oxy-acetylene torch and heated to 550°C for 7 h so that CO 2 could be reduced to graphite (Macario et al, 2015, 2017; Xu et al, 2007). Graphite samples were pressed in aluminium cathodes and their radiocarbon concentration was measured at the Center for Applied Isotope Studies at the University of Georgia (Cherkinsky et al, 2010).…”
Section: Methodsmentioning
confidence: 99%
“…CO 2 samples were then transferred to 9 mm Pyrex tubes previously prepared with titanium hydride and zinc on the bottom and iron powder inside a 6-mm inner tube. Tubes were sealed with an oxy-acetylene torch and heated to 550°C for 7 h so that CO 2 could be reduced to graphite (Macario et al, 2015, 2017; Xu et al, 2007). Graphite samples were pressed in aluminium cathodes and their radiocarbon concentration was measured at the Center for Applied Isotope Studies at the University of Georgia (Cherkinsky et al, 2010).…”
Section: Methodsmentioning
confidence: 99%
“…Chemical treatment of the otolith and mollusk samples followed standard procedures with etching in 0.1M hydrochloric acid followed by hydrolysis in 85% phosphoric acid. The carbon dioxide produced was purified and graphitized in independently sealed Pyrex tubes at 550ºC (Macario et al 2015b, 2017). Fossil calcite and C2 IAEA reference samples were prepared together with unknowns for quality control.…”
Section: Methodsmentioning
confidence: 99%
“…These tubes were previously prepared with titanium hydride and zinc on the bottom and iron powder inside a 6-mm inner tube. Tubes were sealed with an oxy-acetylene torch and heated to 550ºC for 7 hr so that CO 2 could be reduced to graphite (Xu et al 2007;Macario et al 2015Macario et al , 2017. Graphite samples were pressed in aluminum cathodes and their 14 C concentration was measured at the Center for Applied Isotopes Studies at the University of Georgia (samples A01, A02 and A10) or at the NEC SSAMS system of the Fluminense Federal University (samples A03-A09).…”
Section: Accelerator Mass Spectrometrymentioning
confidence: 99%