2021
DOI: 10.1016/j.jmbbm.2021.104663
|View full text |Cite
|
Sign up to set email alerts
|

Fracture behavior of cancellous bone and cancellous bone-PMMA bone cement interface: An experimental study using an integrated methodology (wedge splitting test and Heaviside-based digital image correlation)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 32 publications
1
3
0
Order By: Relevance
“…It is located in the range of 33.0 MPa~51.4 MPa for tensile strength f t which has been reported in related literature [17][18][19][20][21]. The average value of fracture toughness K IC was 1.77 MPa • m 1/2 , which likewise falls within the range of 1.0 MPa • m 1/2 ~2.7 MPa • m 1/2 as reported by related literature [10][11][12][13][14][15][16][17]. In addition, the minimum value f min t of tensile strength was 26.29 MPa.…”
Section: Raw Data Of the Experimentssupporting
confidence: 73%
“…It is located in the range of 33.0 MPa~51.4 MPa for tensile strength f t which has been reported in related literature [17][18][19][20][21]. The average value of fracture toughness K IC was 1.77 MPa • m 1/2 , which likewise falls within the range of 1.0 MPa • m 1/2 ~2.7 MPa • m 1/2 as reported by related literature [10][11][12][13][14][15][16][17]. In addition, the minimum value f min t of tensile strength was 26.29 MPa.…”
Section: Raw Data Of the Experimentssupporting
confidence: 73%
“…Therefore, polyurethane foam is considered a suitable substitute material for cancellous bone in quasi-static tests. In contrast, polyurethane foam shows brittle material behaviour in fracture tests and may not be suitable for this type of testing 49 . A major advantage is that fewer specimens are required with polyurethane foam compared to tests with bone tissue 14 .…”
Section: Discussionmentioning
confidence: 99%
“…Artificial bones (Sawbones, Vashon Islands, WA) employed in biomechanical studies , were used to observe the effect of the shape memory implant on cortical and trabecular bones. A model with a density of 15 pcf (Cellular Foam, Block, #1522-1300) was used as the trabecular bone, and a model produced from short fiber-reinforced epoxy (Solid, Fourth Generation, #3403-11) was used for the cortical bone.…”
Section: Methodsmentioning
confidence: 99%