Free Kappa light chains in neuroinflammatory disorders: Complement rather than substitute?

Abstract: Our results demonstrate that the κFLC index does not discriminate MS from other IND patients, but is a reliable technique to detect intrathecal inflammation. However, κFLC quantification should probably be considered as a complementary method, rather than a substitute, to OCB detection.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
17
0
2

Year Published

2019
2019
2023
2023

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 17 publications
(19 citation statements)
references
References 27 publications
0
17
0
2
Order By: Relevance
“…CSF and blood samples were collected at the Cliniques Universitaires Saint-Luc (Brussels) between March 2005 and March 2018, processed according to international guidelines within 1 hour before storage at −80°C until miRNA extraction. 6,7 PBMCs paired with serum were processed as previously described. 8 The study was conducted stepwise (figure 1).…”
Section: Patientsmentioning
confidence: 99%
See 1 more Smart Citation
“…CSF and blood samples were collected at the Cliniques Universitaires Saint-Luc (Brussels) between March 2005 and March 2018, processed according to international guidelines within 1 hour before storage at −80°C until miRNA extraction. 6,7 PBMCs paired with serum were processed as previously described. 8 The study was conducted stepwise (figure 1).…”
Section: Patientsmentioning
confidence: 99%
“…ROC curve analysis was the strongest for miR-150-5p, with a sensitivity and specificity of 80% and 81%, respectively, an even stronger result than previously shown 19 and comparable to ROC curves of kappa free light chains for MS diagnosis. 7 The set of miRNAs (miR-20a-5p, -145-5p, -214-3p, -27a-3p, -27b-3p, -24-3p, and -29c-3p) whose expression was modified according to disease activity could be sufficient to segregate patients with relapsing MS from patients with remitting MS. Further studies, in larger independent cohorts, should investigate whether these miRNAs could serve as biomarkers of disease activity. MiRNA profile in the serum and PBMCs of patients with MS Five miRNAs were downregulated in the serum of both relapsing and remitting MS (miR-15a-3p, -24-3p, -126-3p, -146a-3p, and -181c-5p), whereas miR-214-3p was downregulated in the serum of relapsing MS only.…”
Section: Csf-predominant Mirna Dysregulation and Mirna Species Newly mentioning
confidence: 99%
“…Kvantifikace fLC pomocí rozdílných reagencií/ přístrojů nemusí poskytovat srovnatelné hodnoty umožňující univerzální použití jediné cut-off hodnoty pro výpočet intratékální syntézy fLC. Diskrepantní výsledky mezi kvantitativními a kvalitativními testy pro fKLC byly publikovány v recentní studii [33]. Přestože se ukázalo, že detekce o-fLC může být nepatrně senzitivnějším testem než o-IgG pro průkaz intratékálního zánětu, může být také méně specifická pro RS než o-IgG [5][6][7][8].…”
Section: Srovnání S Výpočty Intratékální Syntézy Igg a Flcunclassified
“…Přestože se ukázalo, že detekce o-fLC může být nepatrně senzitivnějším testem než o-IgG pro průkaz intratékálního zánětu, může být také méně specifická pro RS než o-IgG [5][6][7][8]. Proto souhlasíme s Bayartem et al [33], že testy fLC by měly být používány spíše jako doplněk než jako náhrada za analýzu o-IgG, jejíž klíčové postavení je zakotveno i v doporučeních českých odborných společností [34,35].…”
Section: Srovnání S Výpočty Intratékální Syntézy Igg a Flcunclassified
“…The gold standard for CSF analysis is isoelectric focusing (IEF) to detect CSF oligoclonal bands (OB) of immunoglobulin (Ig) G. Historically, intrathecal synthesis of IgG has been detected as an elevated immunoglobulin G (IgG) or Link index, calculated as the ratio of CSF/serum IgG to CSF/serum albumin [4]. Recently, measures of free light chains (FLC) by nephelometry have been proposed as an alternative method to IgG index and OB detection by IEF [5]. Despite the role of lambda (λ) FLC remains controversial, there is robust evidence for kappa (K) FLC [6,7].…”
Section: Introductionmentioning
confidence: 99%