Abstract: A multifrequency calorimeter has been designed to measure the amplitude and time regime of the enthalpic fluctuations associated with structural or conformational transitions in biological macromolecular systems. The heat capacity function at constant pressure is directly proportional to the magnitude of the enthalpic fluctuations in a system. Biological macromolecules undergo thermally induced transitions of different kinds. Within the transition region, these systems exhibit relatively large enthalpy fluctua… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
8
0

Year Published

1991
1991
2021
2021

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 21 publications
(9 citation statements)
references
References 11 publications
1
8
0
Order By: Relevance
“…Multifrequency calorimetry experiments were performed on a new version of the instrument originally developed in this laboratory (Mayorga et al, 1988;Freire et al, 1990). A block diagram of this instrument is shown in Fig.…”
Section: Methodsmentioning
confidence: 99%
“…Multifrequency calorimetry experiments were performed on a new version of the instrument originally developed in this laboratory (Mayorga et al, 1988;Freire et al, 1990). A block diagram of this instrument is shown in Fig.…”
Section: Methodsmentioning
confidence: 99%
“…For this kind of analysis specialized and upper class microcalorimeters are required, to obtain very reproducible and reliable data on small amounts of biological material. Besides few very fine home-made instruments [15,16] up to now only three kinds of commercial apparatus (in the experience of the authors) are actually qualified to be used for these studies: the series of DASM instruments of the Academy of Science of the ex-U.R.S.S. (few examples are diffused in U.S. and Western Europe), the more recent equipment of the Microcal (U.S.) and the MICRO DSC and MICRO DSC-II of the Setaram (France).…”
Section: Introductionmentioning
confidence: 99%
“…15 Often, when dealing with the frequency-dependent specific heat, more or less explicit reference is made to the standard FD theorem. 7,12,[16][17][18][19] This, however, is inaccurate since the specific heat is not a response to an external field perturbing the Hamiltonian.…”