2019
DOI: 10.1016/j.asr.2019.01.037
|View full text |Cite
|
Sign up to set email alerts
|

Full characterization of a compact 90Sr/90Y beta source for TID radiation testing

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
5
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
4

Relationship

3
1

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 5 publications
0
5
0
Order By: Relevance
“…The blue dots refer to the spectra of the RCF not exposed to the radiation, whereas the other spectra refer to doses of 4.3, 20, and 43 Gy. These acquisitions have been performed with a 38 MBq 90 Sr/ 90 Y β source [19]. The intensity of the spectrum at 4.3 Gy (magenta) at wavelength λ = 500 nm decreases by 5% with respect to the spectrum at 0 Gy spectrum (cyan) at the same wavelength.…”
Section: Resultsmentioning
confidence: 99%
“…The blue dots refer to the spectra of the RCF not exposed to the radiation, whereas the other spectra refer to doses of 4.3, 20, and 43 Gy. These acquisitions have been performed with a 38 MBq 90 Sr/ 90 Y β source [19]. The intensity of the spectrum at 4.3 Gy (magenta) at wavelength λ = 500 nm decreases by 5% with respect to the spectrum at 0 Gy spectrum (cyan) at the same wavelength.…”
Section: Resultsmentioning
confidence: 99%
“…We already demonstrated the validity of this equation as the calibration equation for B3 films, EBT3 and HDV-2 Gafchromic films analyzed with commercial scanners. 14 In this work, we exposed an XR-QA2 Gafchromic film to beta rays from 90 Sr/ 90 Y source. The reading of the darkening of the film was performed in real-time by means of the new opto-electronic based method.…”
Section: Resultsmentioning
confidence: 99%
“…Recently, we proposed the absolute calibration equation for all RCF types. 14,15 This equation, the Green-Saunders equation, has a general validity since it is the physical law that describes the phenomenon of the film darkening. The fitting parameters of this function have therefore a precise physical meaning related in particular to the film's contrast and dynamics.…”
Section: Introductionmentioning
confidence: 99%
“…The primary application field is in medical physics for dosimetry checks of accelerator beams for particle and radiation therapy [1][2][3]. Its use in industrial applications as material irradiation, food sterilization and radiation hardness is also confirmed by several works [4][5][6][7][8]. In all these applications RCFs are used not only as dosimeters but also as instruments which are capable of providing high-resolution 2D spatial distribution of the radiation field.…”
Section: Introductionmentioning
confidence: 98%