Background
Brugada Syndrome (BrS) is a life-threatening cardiac arrhythmia disorder associated with an increased risk ventricular arrhythmias (VAs) and sudden cardiac death (SCD). Current management primarily relies on implantable cardioverter-defibrillators (ICDs), but patients may experience ICD shocks. Catheter ablation (CA) has emerged as a potential intervention to target the arrhythmogenic substrate. This systematic review aims to evaluate the safety and efficacy of catheter ablation in BrS patients.
Methods and Results
Studies with BrS patients undergoing catheter ablation for VAs were included. 14 studies that involved a total population of 709 BrS patients, with catheter ablation performed in 528 of them, were included. Catheter ablation resulted in non-inducibility of VAs in 91% (95% CI: 83–99, I2 = 76%) and resolution of Type 1 ECG Brugada pattern in 88% (95% CI: 81–96.2, I2 = 91%) of the patients. After a mean follow-up of 30.7 months, 87% (95% CI: 80–94, I2 = 82%) of patients remained free from VAs. The incidence of VAs during follow-up was significantly lower in the ablation cohort in comparison to the group receiving only ICD therapy (OR = 0.03, 95% CI: 0.01–0.12, I2 = 0%).
Conclusion
Catheter ablation shows potential as a therapeutic approach to reduce VAs and improve outcomes in BrS patients. While further research with long follow-up period is required to confirm these findings, it represents a valuable tool as an add-on intervention to ICD implantation in BrS patients with high burden of VAs.
Protocol registration: CRD42024506439