2020
DOI: 10.1016/j.saa.2020.118406
|View full text |Cite
|
Sign up to set email alerts
|

G-quadruplex specific thioflavin T-based label-free fluorescence aptasensor for rapid detection of tetracycline

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0

Year Published

2021
2021
2025
2025

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 23 publications
(10 citation statements)
references
References 45 publications
0
10
0
Order By: Relevance
“…The content of G and C bases in Apt76 is as high as 68.4%, which provides a foundation for the synthesis of AgNCs. In addition, it has been reported that Apt76 in buffer can form a G-quadruplex structure [30],…”
Section: Principle Of the Label-free Biosensor Based On Agncsmentioning
confidence: 99%
“…The content of G and C bases in Apt76 is as high as 68.4%, which provides a foundation for the synthesis of AgNCs. In addition, it has been reported that Apt76 in buffer can form a G-quadruplex structure [30],…”
Section: Principle Of the Label-free Biosensor Based On Agncsmentioning
confidence: 99%
“…S4 †), the rate and mutation abundance showed a linear relation in the range of 0-100%. Compared with other detection methods, [12][13][14][15][16] this method has a lower mutation detection limit and is shorter in time. All the substances used in the Exo III-amplied 4-way strand migration system are relatively low-cost.…”
Section: Detection Limit Of Low Abundance Deletion Mutations In Synth...mentioning
confidence: 99%
“…In order to acquire high sensitivity for EGFR exon 19 deletions, a more simple and efficient design model that combined PCR with rolling circle amplication, graphene oxide, locked nucleic acid and more was researched. [12][13][14] Unfortunately, the cost of the material was relatively expensive, and the sensitivity was limited by PCR itself (the detection limit is about 0.1%). 15,16 The nucleic acid probe methods have the advantages of strong adjustment, simple operation, and rapid detection.…”
Section: Introductionmentioning
confidence: 99%
“…Based on the G4 structure of the TET aptamer, Dai et al developed a label-free aptasensor for TET with ThT as a fluorescent probe . Owing to the aptamer-TET interaction and concomitant disassembly of the G4 structure, the fluorescence intensity gradually decreased with increasing TET concentration, resulting in an LOD of 1 nM (∼0.4 ng mL –1 ).…”
Section: Application Of Fluorescent Aptasensor For the Detection Of F...mentioning
confidence: 99%
“…Based on the G4 structure of the TET aptamer, Dai et al developed a label-free aptasensor for TET with ThT as a fluorescent probe. 165 Owing to the aptamer-TET interaction and concomitant disassembly of the G4 structure, the fluorescence intensity gradually decreased with increasing TET concentration, resulting in an LOD of 1 nM (∼0.4 ng mL −1 ). Relying on the interaction between NM quencher and aptamer-functionalized fluorescent nanoprobes, turn-on fluorescence aptasensors were constructed to detect TET.…”
Section: ■ Application Of Fluorescent Aptasensor For the Detection Of...mentioning
confidence: 99%