Gallbladder Perforation with Conventional Monopolar Diathermy Versus Harmonic Scalpel in Laparoscopic Cholecystectomy at Combined Military Hospital, Quetta

Abstract: Objective: To estimate the frequency of gallbladder perforation with conventional Monopolar Diathermy versus Harmonic scalpel in laparoscopic cholecystectomy. Study Design: Quasi-experimental study. Place and Duration of Study: Department of Surgery, Combined Military Hospital, Quetta Pakistan, from Sep 2018 to Sep 2019. Methodology: A total of 160 patients undergoing laparoscopic cholecystectomy for symptomatic gallstones were included in the study and were randomly allocated into two groups… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
0
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(2 citation statements)
references
References 11 publications
0
0
0
Order By: Relevance
“…The ultrasonic device retains the operative zone blood less, which aids the less expert in identifying the proper plane, shortened operational clock, lower incidence of gallbladder perforation, lower postoperative discomfort and lower number conversions. 14 Therefore, its feasibility, handling and the superior performance of the ultrasonic device urges surgeons to expand its function and embrace it as a viable alternative to normal clipping. 14 However, the primary constraint of using this approach is the lack of availability, the needed experience, and the pricey apparatus, which is tough to get in a resource-constrained nation.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The ultrasonic device retains the operative zone blood less, which aids the less expert in identifying the proper plane, shortened operational clock, lower incidence of gallbladder perforation, lower postoperative discomfort and lower number conversions. 14 Therefore, its feasibility, handling and the superior performance of the ultrasonic device urges surgeons to expand its function and embrace it as a viable alternative to normal clipping. 14 However, the primary constraint of using this approach is the lack of availability, the needed experience, and the pricey apparatus, which is tough to get in a resource-constrained nation.…”
Section: Introductionmentioning
confidence: 99%
“…14 Therefore, its feasibility, handling and the superior performance of the ultrasonic device urges surgeons to expand its function and embrace it as a viable alternative to normal clipping. 14 However, the primary constraint of using this approach is the lack of availability, the needed experience, and the pricey apparatus, which is tough to get in a resource-constrained nation. Methodology: This Prospective comparative study was conducted over a Six months from march 2021 to January 2022 in department of general surgery at Liaquat University Hospital Jamshoro.…”
Section: Introductionmentioning
confidence: 99%