GATE Simulation of $^{12}{\rm C}$ Hadrontherapy Treatment Combined With a PET Imaging System for Dose Monitoring: A Feasibility Study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
11
0

Year Published

2013
2013
2020
2020

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 15 publications
(11 citation statements)
references
References 34 publications
0
11
0
Order By: Relevance
“…A comparison between results and data from the literature obtained using different codes (MCNP, EGS, FLUKA, ETRAN, GEPTS, and PENELOPE) showed a general agreement within 6%. An additional DPK dataset was then generated for other radionuclides of interest ( 67 Ga, 68 Ga, 123 I, 124 I, 125 I, 153 Sm, 186 Re, and 188 Re). The conclusion is that current MC codes-including GATE-now provide equivalent results for "standard" situations, involving photon/electron transport for energies of interest in nuclear medicine.…”
Section: A1 Dose Point Kernelmentioning
confidence: 99%
See 2 more Smart Citations
“…A comparison between results and data from the literature obtained using different codes (MCNP, EGS, FLUKA, ETRAN, GEPTS, and PENELOPE) showed a general agreement within 6%. An additional DPK dataset was then generated for other radionuclides of interest ( 67 Ga, 68 Ga, 123 I, 124 I, 125 I, 153 Sm, 186 Re, and 188 Re). The conclusion is that current MC codes-including GATE-now provide equivalent results for "standard" situations, involving photon/electron transport for energies of interest in nuclear medicine.…”
Section: A1 Dose Point Kernelmentioning
confidence: 99%
“…In Ref. 123, the authors simulated with GATE a carbon ion beam plan coupled with a complete PET ECAT EXACT HR+ system and demonstrated the need for simulating the full PET system instead of only smoothing the simulated positron emitter maps using a Gaussian function. Differences in the distal position of the signal fall-off of 20% were observed between the full PET system simulation and a simple convolution model.…”
Section: F2 Hadron-pet Studiesmentioning
confidence: 99%
See 1 more Smart Citation
“…It has been developed by the OpenGate collaboration and encapsulates the GEANT4 libraries, providing a toolkit mostly oriented to nuclear medicine by easily including detailed geometry of many imaging devices. It has been tested in the context of particle therapy, especially for range monitoring applications [24][25][26].…”
Section: Geant4mentioning
confidence: 99%
“…The developments provided new features, such as the modeling of moving sources and motion, thus allowing for IMRT and arc therapy applications. A carbon ion therapy application combining radiation therapy modeling and emission tomography was presented as a proof of concept of the combined imaging and dosimetric, time-resolved, capabilities of the GATE platform 2,4 . In this paper, the terminology Light Ion Beam Therapy (LIBT) is used 5 .…”
Section: Introductionmentioning
confidence: 99%