Abstract: Abstract:Voltage instability is a crucial issue in the secure operation of power grids. Several methods for voltage stability assessment were presented. Some of them are highly computationally intensive, while others are reported not to work properly under all circumstances. This paper proposes a new methodology based on the generator equivalent circuit model (GECM) and the phasor measurement unit (PMU) technology for online voltage stability monitoring of a power grid. First, the proposed methodology utilizes… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 28 publications
0
3
0
Order By: Relevance
“…To consider the limits violation of generator reactive power, the previous index TVSM can be extended by incorporating internal model for generators based on their dynamic models and nodal measurements. Based on [44], synchronous generators can be represented by an internal voltage 𝐸 𝐺 in series with an impedance 𝑍 𝐺 . For the 4 th order generator, the internal impedance and voltage can be obtained as [44]:…”
Section: 2mentioning
confidence: 99%
See 1 more Smart Citation
“…To consider the limits violation of generator reactive power, the previous index TVSM can be extended by incorporating internal model for generators based on their dynamic models and nodal measurements. Based on [44], synchronous generators can be represented by an internal voltage 𝐸 𝐺 in series with an impedance 𝑍 𝐺 . For the 4 th order generator, the internal impedance and voltage can be obtained as [44]:…”
Section: 2mentioning
confidence: 99%
“…Based on [44], synchronous generators can be represented by an internal voltage 𝐸 𝐺 in series with an impedance 𝑍 𝐺 . For the 4 th order generator, the internal impedance and voltage can be obtained as [44]:…”
Section: 2mentioning
confidence: 99%
“…Since the advancement of wide-area measurement system (WAMS) based on synchronized phasor measurements has made it possible to gain real-time information of transient stability status in power systems [2], power system transient stability assessment and emergency control have received renewed interests [3][4][5]. However, online transient rotor angle stability assessment is confronted with some serious challenges due to the increasing scale and more complex dynamics of power systems.…”
Section: Introductionmentioning