2003
DOI: 10.1016/s0003-2670(03)00818-3
|View full text |Cite
|
Sign up to set email alerts
|

Gel-surface enhanced fluorescence sensing system coupled to a continuous-flow assembly for simultaneous monitoring of benomyl and carbendazim

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
7
0

Year Published

2005
2005
2021
2021

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 35 publications
(7 citation statements)
references
References 36 publications
0
7
0
Order By: Relevance
“…A novel, versatile and sensitive continuous-flow on-line solid phase fluorescence based system is proposed for the simultaneous determination of benomyl and carbendazim [77]. The continuous-flow system is based on the on-line preconcentration and resolution of the pesticides on a solid sensing zone, followed by the sequential measure of their native fluorescence, monitored at 235/306 and 293/398nm (λ exc /λ em for carbendazim and benomyl, respectively), and later desorption of these analytes (from the flow-through cell filled with C 18 silica gel) using aqueous methanol mixtures as carrier and eluent solutions.…”
Section: Fluorescencementioning
confidence: 99%
“…A novel, versatile and sensitive continuous-flow on-line solid phase fluorescence based system is proposed for the simultaneous determination of benomyl and carbendazim [77]. The continuous-flow system is based on the on-line preconcentration and resolution of the pesticides on a solid sensing zone, followed by the sequential measure of their native fluorescence, monitored at 235/306 and 293/398nm (λ exc /λ em for carbendazim and benomyl, respectively), and later desorption of these analytes (from the flow-through cell filled with C 18 silica gel) using aqueous methanol mixtures as carrier and eluent solutions.…”
Section: Fluorescencementioning
confidence: 99%
“…There are various analytical methods for the analysis of BN in different samples: Liquid chromatography [1,2], fluorimetry [3,4], fluorescence polarization [5], and modulated anisotropy fluorescence [6] have been reported in the literature. However, in order to determine trace amounts of the fungicide, development of novel methods with higher sensitivities, precision, and accuracy is necessary.…”
Section: Introductionmentioning
confidence: 99%
“…So far, a variety of available methods have been developed for the detection of carbendazim, including fluorescence analysis, [11] capillary electrophoresis, [12] spectrophotometry, [13] and liquid chromatography. [14] However, these analyses methods have some shortcomings, such as complex pretreatment procedures for materials containing detection substances, long detection time, complex operation procedures, and expensive equipment.…”
Section: Introductionmentioning
confidence: 99%