2013
DOI: 10.1109/jlt.2013.2286267
|View full text |Cite
|
Sign up to set email alerts
|

Generalized Spectral Magnitude and Phase Retrieval Algorithm for Self-Referenced Multiheterodyne Detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
3
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 18 publications
0
3
0
Order By: Relevance
“…Because the probe comb consisted of only a few hundred comb teeth, a digital lock-in algorithm [35] instead of the usual fast Fourier transform [19] was used to retrieve both the amplitude and phase of all down-converted comb teeth from the time-domain interferograms [20,21]. Challenges in discrete time-domain sampling like the scalloping of down-converted comb teeth [36] are avoided entirely owing to the frequency-agile, digital control of f mod , Δf mod , and f AOM . Fig.…”
Section: Long-term Coherence Without Complexitymentioning
confidence: 99%
“…Because the probe comb consisted of only a few hundred comb teeth, a digital lock-in algorithm [35] instead of the usual fast Fourier transform [19] was used to retrieve both the amplitude and phase of all down-converted comb teeth from the time-domain interferograms [20,21]. Challenges in discrete time-domain sampling like the scalloping of down-converted comb teeth [36] are avoided entirely owing to the frequency-agile, digital control of f mod , Δf mod , and f AOM . Fig.…”
Section: Long-term Coherence Without Complexitymentioning
confidence: 99%
“…Multiheterodyne techniques are linear, applicable to OAW with large mode spacing, and can work with reduced RF bandwidth. However, they need reference combs with different mode spacings and controllable carrier-envelope-offset frequencies [17].In this Letter, we report on what is, to our best knowledge, the first self-referenced OAW measurement experiment using an orthogonally probed DQ-SSI system implemented by a polarization line-by-line pulse shaper. We know that a (scalar) pulse shaper has been applied to a variety of pulse measurement techniques [9,[18][19][20] with the advantages of eliminating extra dispersion due to typical interferometer setup, simultaneous measurement and shaping, improved precision of system calibration, and ultrahigh sensitivity.…”
mentioning
confidence: 98%
“…Multiheterodyne techniques are linear, applicable to OAW with large mode spacing, and can work with reduced RF bandwidth. However, they need reference combs with different mode spacings and controllable carrier-envelope-offset frequencies [17].…”
mentioning
confidence: 99%