2006
DOI: 10.1016/j.jastp.2005.08.024
|View full text |Cite
|
Sign up to set email alerts
|

Geocoronal hydrogen studies using Fabry–Perot interferometers, part 1: Instrumentation, observations, and analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
97
0
1

Year Published

2008
2008
2017
2017

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 32 publications
(99 citation statements)
references
References 61 publications
1
97
0
1
Order By: Relevance
“…The Arequipa nightglow images are analyzed using the method of annular summing spectroscopy described by Coakley et al (1996), Mierkiewicz et al (2006), andNossal et al (2006). By imaging the FPI circular interference pattern onto the face of the thermo-electrically cooled bare CCD chip (high quantum efficiency) and then integrating the nightglow images around the center of this pattern to convert the image into a spectrum, the ratio of signal to noise is much improved.…”
Section: Data Analysis: Determination Of the Spectrummentioning
confidence: 99%
“…The Arequipa nightglow images are analyzed using the method of annular summing spectroscopy described by Coakley et al (1996), Mierkiewicz et al (2006), andNossal et al (2006). By imaging the FPI circular interference pattern onto the face of the thermo-electrically cooled bare CCD chip (high quantum efficiency) and then integrating the nightglow images around the center of this pattern to convert the image into a spectrum, the ratio of signal to noise is much improved.…”
Section: Data Analysis: Determination Of the Spectrummentioning
confidence: 99%
“…Since Fabry-Pérot spectrometers offer the advantage of simultaneously achieving high throughput and high spectral resolution, they are used to obtain high-resolution spectra of very faint, extended diffuse emission line objects of the ISM such as H II regions and PNe (Roesler 1974;Tufte 1997;Mierkiewicz et al 2006 spectral resolution (Sahan et al 2005(Sahan et al , 2007. After completing test observations in the zenith direction, the spectrometer was supported by TUBITAK (The Scientific and Technical Research Council of Turkey) with grant number 104T252 to explore ionized gas in ISM with a spatial resolution of 4 .…”
Section: Defpos Spectrometermentioning
confidence: 99%
“…1999; Mierkiewicz et al 2006). The post-étalon (or the exit) optics including a combination of two lenses with an effective focal length of ≈17 cm, were used to image the Fabry-Pérot s annular interference pattern onto 1.0 cm 2 region the CCD, which can record many spectral elements simultaneously.…”
Section: Defpos Spectrometermentioning
confidence: 99%
See 1 more Smart Citation
“…The Balmer α line of hydrogen differs in wavelength from the Balmer α line of deuterium by 82 km s −1 (1.78 Å) [10,11,24]. The purpose of this method is to be able to determine the wavelength interval that corresponds to an annular area on the chip.…”
Section: Intensity Calibrationmentioning
confidence: 99%