Abstract:A steady state simulation procedure is proposed to capture localized flow reversal inside of a centrifugal compressor vaneless diffuser. The procedure was performed on 12 compressor stages of varying geometry for speed lines of 13,100, 19,240, and 21,870 r/min. The simulations were run for all points from choke to surge including the experimentally determined rotating stall onset point. The experimental data and geometry were provided by Solar Turbines Inc. San Diego, CA. It was found possible to capture local… Show more
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.