Glycerol methacrylate-based copolymers: Reactivity ratios, physicochemical characterization and cytotoxicity

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 62 publications
1
3
0
Order By: Relevance
“…In contrast, a noticeable increase in the M n and Ð values (Table 2) and modification of the molar mass distribution towards higher molar mass values (Figure 4) were observed for polymer P2. This observation may be ascribed to the rise of possible interactions between P(GMMA) polymer chains via hydrogen bonding during the dialysis process, as suggested elsewhere [43], which may promote the formation of polymer species of different molar mass and, therefore, the modification of the hydrodynamic volume of such polymer chains during the respective SEC analyses. This behavior can also be related to the presence of water traces (in our case, most likely derived from the dialysis process), which may remain in the respective polymer samples, as suggested elsewhere [45,46].…”
Section: Resultssupporting
confidence: 51%
See 2 more Smart Citations
“…In contrast, a noticeable increase in the M n and Ð values (Table 2) and modification of the molar mass distribution towards higher molar mass values (Figure 4) were observed for polymer P2. This observation may be ascribed to the rise of possible interactions between P(GMMA) polymer chains via hydrogen bonding during the dialysis process, as suggested elsewhere [43], which may promote the formation of polymer species of different molar mass and, therefore, the modification of the hydrodynamic volume of such polymer chains during the respective SEC analyses. This behavior can also be related to the presence of water traces (in our case, most likely derived from the dialysis process), which may remain in the respective polymer samples, as suggested elsewhere [45,46].…”
Section: Resultssupporting
confidence: 51%
“…The NH is connected to a solvent reservoir bottle for needle rinsing after each liquid transfer. Further details about the characteristics and capabilities of the Chemspeed ASW 2000 platform can be found elsewhere [42][43][44]. For the proposed APD method (Figure 2), a custom-made rack (Figure 2D) was employed to house the utilized and commercially available Float-A-Lyzer ®® G2 dialysis tubes (Figure 2C).…”
Section: Chemspeed Asw2000 Automated Parallel Synthesizer (Aps)mentioning
confidence: 99%
See 1 more Smart Citation
“…[14][15][16][17] Interestingly, amphiphilic copolymer structures can be prepared in both gradient and block configuration with one monomer unit being hydrophilic and the other hydrophobic so that the hydrodynamic properties change along the chain. [18][19][20][21][22][23] This leads to a unique capability of self-assembly in solutions as a response to external stimuli such as pH, 24,25 temperature [26][27][28] or the nature of the solvent. 22,23 Due to this behavior, amphiphilic copolymers can be found in several biomedical applications including tissue engineering, drug delivery, carriers for gene therapy, and cell encapsulation.…”
Section: Introductionmentioning
confidence: 99%