2020
DOI: 10.1016/j.nutres.2020.08.005
|View full text |Cite
|
Sign up to set email alerts
|

Greater cumulative exposure to a pro‐inflammatory diet is associated with higher metabolic syndrome score and blood pressure in young Mexican adults

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
18
1

Year Published

2022
2022
2024
2024

Publication Types

Select...
4
2

Relationship

1
5

Authors

Journals

citations
Cited by 13 publications
(20 citation statements)
references
References 30 publications
1
18
1
Order By: Relevance
“…Trained research staff collected duplicate measurements for body weight (kilograms [kg]) to the nearest 0.1 kg and height (centimeters [cm]) to the nearest 0.5 cm using in Time 1 a digital scale (BAME Model 420; Catálogo Médico/Tanita Co. Tokyo, Japan with height rod (model WB-3000m [38]), and only for weight in Time 2 and 3 the body composition device Inbody (model 230, Seoul, Korea). For waist circumference (cm), duplicate measurements were also performed to the nearest 0.1 cm using a non-stretchable measuring tape (SECA (model 201, Hamburg, Germany [38])). The average of the two measurements was used for the analysis [46].…”
Section: Anthropometric Measuresmentioning
confidence: 99%
See 4 more Smart Citations
“…Trained research staff collected duplicate measurements for body weight (kilograms [kg]) to the nearest 0.1 kg and height (centimeters [cm]) to the nearest 0.5 cm using in Time 1 a digital scale (BAME Model 420; Catálogo Médico/Tanita Co. Tokyo, Japan with height rod (model WB-3000m [38]), and only for weight in Time 2 and 3 the body composition device Inbody (model 230, Seoul, Korea). For waist circumference (cm), duplicate measurements were also performed to the nearest 0.1 cm using a non-stretchable measuring tape (SECA (model 201, Hamburg, Germany [38])). The average of the two measurements was used for the analysis [46].…”
Section: Anthropometric Measuresmentioning
confidence: 99%
“…Fasting blood samples were used to analyze serum glucose via automated chemiluminescence immunoassay (Immulite ® 1000; Siemens Medical Solutions, Erlangen, Germany) [46], and TG and HDL-C using a biochemical analyzer (Cobas Mira Plus; Roche Diagnostics) [46]. Levels of insulin were quantified via enzyme-linked immunosorbent assay chemiluminescence method with Immulite ® 1000; Siemens Medical Solutions, Erlangen, Germany [38]. A HOMA-IR was calculated as [fasting plasma glucose (mmol/L) × fasting serum insulin (mU/L))/22.5]; higher values represent lower insulin sensitivity/insulin resistance [47].…”
Section: Cardiometabolic Biomarkersmentioning
confidence: 99%
See 3 more Smart Citations