2013 IEEE Rural Electric Power Conference (REPC) 2013
DOI: 10.1109/repcon.2013.6681854
|View full text |Cite
|
Sign up to set email alerts
|

Grid impacts due to increased penetration of newer harmonic sources

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
19
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 25 publications
(19 citation statements)
references
References 1 publication
0
19
0
Order By: Relevance
“…Single phase non-linear loads such as energy efficient home appliances are the most significant source of ZS harmonics. It is quite common to observe high levels of ZS harmonics in a distribution substation feeding residential loads these days [2,5,9].…”
Section: A Zero-sequence Harmonic Mitigation Techniquesmentioning
confidence: 99%
See 1 more Smart Citation
“…Single phase non-linear loads such as energy efficient home appliances are the most significant source of ZS harmonics. It is quite common to observe high levels of ZS harmonics in a distribution substation feeding residential loads these days [2,5,9].…”
Section: A Zero-sequence Harmonic Mitigation Techniquesmentioning
confidence: 99%
“…These new harmonic sources have comparable sizes and are distributed all over a network. Although they produce insignificant amount harmonic currents individually, the collective effect of a large number of such loads can be substantial [1][2][3][4][5][6]. Several power quality concerns have been identified due to such distributed harmonic sources [1][2][3][5][6][7][8][9].…”
Section: Introductionmentioning
confidence: 99%
“…In their algorithm, the relation between harmonic current and corresponding harmonic impedance has been established by field measurements. In another study, detailed harmonic analysis of actual circuit models has been presented to predict the response of distribution systems to harmonic loads in coming years . Wang et al have presented a comparative analysis of harmonic distortions caused by residential, industrial, and commercial feeders.…”
Section: Introductionmentioning
confidence: 99%
“…In another study, detailed harmonic analysis of actual circuit models has been presented to predict the response of distribution systems to harmonic loads in coming years. 25 Wang et al 26 have presented a comparative analysis of harmonic distortions caused by residential, industrial, and commercial feeders. Their results show that harmonic currents from residential consumers are considerably larger than those of commercial and industrial consumers.…”
Section: Introductionmentioning
confidence: 99%
“…A first attempt to evaluate the different types of new harmonic sources has been made [8]. Here, a detailed harmonic analysis has been conducted on actual circuits with mixed harmonic loads, which may be projected on the distribution network in 10-20 years.…”
Section: Introductionmentioning
confidence: 99%