2024
DOI: 10.1016/j.echo.2023.10.004
|View full text |Cite
|
Sign up to set email alerts
|

Guidelines for the Evaluation of Prosthetic Valve Function With Cardiovascular Imaging: A Report From the American Society of Echocardiography Developed in Collaboration With the Society for Cardiovascular Magnetic Resonance and the Society of Cardiovascular Computed Tomography

William A. Zoghbi,
Pei-Ni Jone,
Mohammed A. Chamsi-Pasha
et al.
Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
33
0
12

Year Published

2024
2024
2025
2025

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 23 publications
(45 citation statements)
references
References 228 publications
0
33
0
12
Order By: Relevance
“…Postoperative stroke can occur due to embolisms from calcified plaques or valve handling with attached vegetation. Postoperatively, the incidence of stroke is variable, between 2 and 11% [ 49 , 62 ]. The diagnosis of postoperative stroke is made by close clinical examination upon awakening.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Postoperative stroke can occur due to embolisms from calcified plaques or valve handling with attached vegetation. Postoperatively, the incidence of stroke is variable, between 2 and 11% [ 49 , 62 ]. The diagnosis of postoperative stroke is made by close clinical examination upon awakening.…”
Section: Discussionmentioning
confidence: 99%
“…In selected situations, TTE evaluation is complemented by TOE for the further refinement of valve function and morphology. Cardiac magnetic resonance (MRI) and cardiac computed tomography (CT) have recently improved their role in cardiac valve evaluation [ 49 ].…”
Section: Literature Reviewmentioning
confidence: 99%
“…A complementação tridimensional (3D) melhora a definição espacial, acrescentando a capacidade de determinar o caminho de um vazamento, que muitas vezes pode seguir um curso serpiginoso. 10 De forma superficial, as primeiras informações a serem verificadas e confirmadas são gravidade, localização, tamanho, forma e o número de vazamentos. Inicialmente, a prótese valvar é "escaneada" por meio de uma sistemática rotação da sonda de eco, que busca a presença de deiscência e/ou sinais paraprotéticos com o Doppler colorido.…”
Section: Introductionunclassified
“…Nesses casos, a abordagem transcateter está contraindicada e a avaliação de cirurgia convencional deve ser realizada o mais rápido possível (Vídeo 1). 6,10 Descartada essa complicação, os parâmetros do Doppler precisam ser avaliados, conforme encontramos na Tabela 1.…”
Section: Introductionunclassified
See 1 more Smart Citation