2011
DOI: 10.2478/s11534-011-0096-2
|View full text |Cite
|
Sign up to set email alerts
|

Gwyddion: an open-source software for SPM data analysis

Abstract: Ê Ú ¼ ÂÙÐÝ ¾¼½½ ÔØ ½¿ ÇØÓ Ö ¾¼½½ ×ØÖ ØIn this article, we review special features of Gwyddiona modular, multiplatform, open-source software for scanning probe microscopy data processing, which is available at http://gwyddion.net/ . We describe its architecture with emphasis on modularity and easy integration of the provided algorithms into other software. Special functionalities, such as data processing from non-rectangular areas, grain and particle analysis, and metrology support are discussed as well. It is… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

7
2,584
0
13

Year Published

2015
2015
2024
2024

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 3,118 publications
(2,604 citation statements)
references
References 15 publications
7
2,584
0
13
Order By: Relevance
“…Silicon cantilevers with a spring constant of 40 N m −1 and a resonance frequency of 300 kHz were used in tapping mode; data were further processed using Gwyddion. [35] VTIV Measurements: VTIV measurements were carried out on 95 nm thick films evaporated on a quartz substrate prepatterned with interdigitated gold electrodes. The spacing between electrodes was 80 µm.…”
Section: Experimental Methodsmentioning
confidence: 99%
“…Silicon cantilevers with a spring constant of 40 N m −1 and a resonance frequency of 300 kHz were used in tapping mode; data were further processed using Gwyddion. [35] VTIV Measurements: VTIV measurements were carried out on 95 nm thick films evaporated on a quartz substrate prepatterned with interdigitated gold electrodes. The spacing between electrodes was 80 µm.…”
Section: Experimental Methodsmentioning
confidence: 99%
“…As described elsewhere for ferrite evaluation [20], the optimum settings for imaging were determined to be a lift height of 50 nm, drive amplitude-based noise reduction, a step size of 170 nm and a scan rate of 0.54 Hz. The AFM/MFM data were analysed with the Gwyddion 2.30 [29] open source scanning probe microscopy analysis software (http://gwyd dion.net/; Czech Metrology Institute, Brno, Czech Republic). Data processing used the procedure detailed previously [20], and ferrite quantification used a combined manual and automated thresholding procedure.…”
Section: Methodsmentioning
confidence: 99%
“…Secondary electron mode was applied with 20 kV accelerating voltage. Additionally, the SEM-based grain size at diamond surface was analysed via graphical profiling tool of the computer software for data visualization and analysis (Gwyddion, 2.40, Czech Republic) [44].…”
Section: Semmentioning