2019
DOI: 10.1117/1.nph.6.4.041102
|View full text |Cite
|
Sign up to set email alerts
|

Handheld spectrally encoded coherence tomography and reflectometry for motion-corrected ophthalmic optical coherence tomography and optical coherence tomography angiography

Abstract: Optical coherence tomography (OCT) is the gold standard for quantitative ophthalmic imaging. The majority of commercial and research systems require patients to fixate and be imaged in a seated upright position, which limits the ability to perform ophthalmic imaging in bedridden or pediatric patients. Handheld OCT devices overcome this limitation, but image quality often suffers due to a lack of real-time aiming and patient eye and photographer motion. We describe a handheld spectrally encoded coherence tomogr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
11
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5
2
1
1

Relationship

1
8

Authors

Journals

citations
Cited by 30 publications
(49 citation statements)
references
References 54 publications
0
11
0
Order By: Relevance
“…The OCT volumes were acquired with 2560 × 500 × 400 × 4 pix. (spectral × lines × frames × repeated frames) [23,6]. OCT-A is performed on motion-corrected [11] OCT volumes using singular value decomposition.…”
Section: Methodsmentioning
confidence: 99%
“…The OCT volumes were acquired with 2560 × 500 × 400 × 4 pix. (spectral × lines × frames × repeated frames) [23,6]. OCT-A is performed on motion-corrected [11] OCT volumes using singular value decomposition.…”
Section: Methodsmentioning
confidence: 99%
“…Demonstrations of (partly) miniaturized OCT systems in research have been accomplished in ophthalmic care using handheld probes, 330,[334][335][336][337][338][339][340][341][342][343] off-the-shelf micro-optical components 52,334,344 or PICs 329,345,346 for dermatologic care using handheld probes, [347][348][349][350][351][352][353] compact packaging of offthe-shelf components, 354 PICs, 353,[355][356][357] and handheld probes for oral 358 and for inner ear [359][360][361][362] imaging. The usage of off-the-shelf microcomponents seems to be the most mature technique for miniaturized OCT at the moment.…”
Section: Oct and Deep Learning Neural Network And Artificial Intelligencementioning
confidence: 99%
“…For instance, fundus examination with an ophthalmoscope is required after pupil dilation to confirm myopia and determine the stage. Furthermore, handheld spectroscopically coded coherence tomography and reflection (SECTR) systems are commonly used for eye inspection 33 . The handheld probe uses a custom dual-pass scanning lens for full telecentric optical coherence tomography (OCT) scanning.…”
Section: Existing Challenges Of Common Devicesmentioning
confidence: 99%