Proceedings 12th International Conference on Advances in Steel-Concrete Composite Structures - ASCCS 2018 2018
DOI: 10.4995/asccs2018.2018.7151
|View full text |Cite
|
Sign up to set email alerts
|

Headed studs close to concrete edge under pull-out

Abstract: The capacity of the headed studs when they are close to the edge may be limited by the splitting forces in the concrete. In the Eurocode 4 Part 2 Annex C the shear capacity under this particular arrangement of the studs, which is directly dependent on the distance to the edge, is formulated. In addition, the geometrical restrictions to prevent the failure by pull-out of the studs are also given in clause C1 (2). These rules are based on push-out tests for the edge position where tension forces in the lying stu… Show more