2020
DOI: 10.1109/tim.2019.2958582
|View full text |Cite
|
Sign up to set email alerts
|

Headspace Oxygen Concentration Measurement for Pharmaceutical Glass Bottles in Open-Path Optical Environment Using TDLAS/WMS

Abstract: Accurate measurement of oxygen concentration for pharmaceutical glass bottles is of great significance to ensure the asepsis of medicine and stability of ingredients. With merits of high sensitivity, low cost, non-contact, and real time response, the wavelength-modulation-based tunable diode laser absorption spectroscopy (TDLAS/WMS) technology shows great potential to achieve in-site oxygen concentration detection by the single-line spectrum measurement. This paper focuses on headspace oxygen concentration mea… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
11
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 42 publications
(11 citation statements)
references
References 30 publications
0
11
0
Order By: Relevance
“…3), where our proposed EWT-ASG algorithm will be carried out and verified. It is worth to mention that the parameters and configurations of this prototype are the same as our previous work [1] and the temperature range in the workshop is 25°C to 32°C.The raw 2nd harmonics of 0% oxygen concentration for pharmaceutical glass bottle are obtained, taking one of the raw 2nd harmonics as an example for subsequent analysis and discussion, then a 2nd harmonic f(k) is shown in Fig. 4 (black dashed line).…”
Section: Experiments Detailsmentioning
confidence: 99%
See 4 more Smart Citations
“…3), where our proposed EWT-ASG algorithm will be carried out and verified. It is worth to mention that the parameters and configurations of this prototype are the same as our previous work [1] and the temperature range in the workshop is 25°C to 32°C.The raw 2nd harmonics of 0% oxygen concentration for pharmaceutical glass bottle are obtained, taking one of the raw 2nd harmonics as an example for subsequent analysis and discussion, then a 2nd harmonic f(k) is shown in Fig. 4 (black dashed line).…”
Section: Experiments Detailsmentioning
confidence: 99%
“…4 to show the performance of our proposed SWT-ASG algorithm. To be consistent with the Reference [1], which used discrete-time wavelet packet transform (DWPT) with different mother wavelet functions to generate the signal reconstructor, we choose the same three typical wavelet functions of Coiflets, Symlets and Meyer as mother wavelet function, where the amplitude drop is in accord with the result in [1] when using Meyer. As the waveform of Meyer has a considerable discrepancy with the ideal 2nd harmonic, the result of the convolution of the raw 2nd signal with the infinite impulse response filter can not fit the symmetric 2nd harmonic well.…”
Section: Signal Reconstruction Performancementioning
confidence: 99%
See 3 more Smart Citations