Companion Publication of the 2020 International Conference on Multimodal Interaction 2020
DOI: 10.1145/3395035.3425323
|View full text |Cite
|
Sign up to set email alerts
|

Heart Rate Detection from the Supratrochlear Vessels using a Virtual Reality Headset integrated PPG Sensor

Abstract: An increasing amount of virtual reality (VR) research is carried out to support the vast number of applications across mental health, exercise and entertainment fields. Often, this research involves the recording of physiological measures such as heart rate recordings with an electrocardiogram (ECG). One challenge is to enable remote, reliable and unobtrusive VR and heart rate data collection which would allow a wider application of VR research and practice in the field in future. To address the challenge, thi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
3
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
3
1

Relationship

2
2

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 18 publications
0
3
0
Order By: Relevance
“…Real-time signal quality measures described below can be used to ensure data with low noise to signal ratio is captured. Multiple validation studies (Fatoorechi et al, 2017;Mavridou et al, 2017c;Mavridou et al, 2018a;Mavridou et al, 2019b;Governo et al, 2020;Gnacek et al, 2020;Lou et al, 2020) and white papers (emteqlabs, 2020a, 2020b, 2021) have already been published to showcase emteqPRO's viability and potential use across a wide spectrum of applications.…”
Section: Emteqpro Hardwarementioning
confidence: 99%
See 1 more Smart Citation
“…Real-time signal quality measures described below can be used to ensure data with low noise to signal ratio is captured. Multiple validation studies (Fatoorechi et al, 2017;Mavridou et al, 2017c;Mavridou et al, 2018a;Mavridou et al, 2019b;Governo et al, 2020;Gnacek et al, 2020;Lou et al, 2020) and white papers (emteqlabs, 2020a, 2020b, 2021) have already been published to showcase emteqPRO's viability and potential use across a wide spectrum of applications.…”
Section: Emteqpro Hardwarementioning
confidence: 99%
“…Nailfold capillaroscopy of the forehead region has shown similar capillary density to the finger and forearm (Toll, 2020). A density of capillary coverage makes the forehead wellsuited as a placement location (Branson and Mannheimer, 2004) and can be used to detect changes to blood flow (Otsuka et al, 2017) and accurately measure heart rate features such as beats per minute (Gnacek et al, 2020) to reflect changes in arousal. Moreover, a proximity sensor is used to measure the amount of ambient incident light that reaches the sensor.…”
Section: Ppg Sensormentioning
confidence: 99%
“…1). Previous studies robustly validated emteqPRO sensors for heart rate detection 23 , facial expressions 24 , breathing rate estimation 25 , valence and arousal 26,27 , and even pain perception 28 , enabling us to use this device to generate a novel, comprehensive database.…”
mentioning
confidence: 99%