Heat Sterilization Effects on Polymeric, FDM-Optimized Orthopedic Cutting Guide for Surgical Procedures

Abstract: Improvements in software for image analysis have enabled advances in both medical and engineering industries, including the use of medical analysis tools to recreate internal parts of the human body accurately. A research analysis found that FDM-sourced elements have shown viability for a customized and reliable approach in the orthopedics field. Three-dimensional printing has allowed enhanced accuracy of preoperative planning, leading to reduced surgery times, fewer unnecessary tissue perforations, and fewer … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
2

Relationship

1
6

Authors

Journals

citations
Cited by 11 publications
(9 citation statements)
references
References 73 publications
0
9
0
Order By: Relevance
“…Therefore, PLA’s low resistance to sterilization processes is expected to limit its wide use in single-use surgical devices. Frizziero et al (2021) studied 3D printed parts based on PLA subjected to a regular heat-sterilization cycle and they observed that 3D-PLA-based parts mainly maintained the geometry after a moist heat (MH) sterilization process conducted in an autoclave [ 21 ]. However, although PLA can maintain its geometry after the sterilization process, the mechanical resistance of such surgical devices is of fundamental importance and should be extensively studied.…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, PLA’s low resistance to sterilization processes is expected to limit its wide use in single-use surgical devices. Frizziero et al (2021) studied 3D printed parts based on PLA subjected to a regular heat-sterilization cycle and they observed that 3D-PLA-based parts mainly maintained the geometry after a moist heat (MH) sterilization process conducted in an autoclave [ 21 ]. However, although PLA can maintain its geometry after the sterilization process, the mechanical resistance of such surgical devices is of fundamental importance and should be extensively studied.…”
Section: Introductionmentioning
confidence: 99%
“…The significance level was 0.05. Many studies addressed the accuracy of 3D-printed surgical guide made of different materials and subjected to sterilization [26][27][28][29]. The rationale of these studies relates to the practical observations that some sterilization techniques can determine deformations of the surgical guides with critical impact on accuracy and the functionality of the device [13].…”
Section: Results Of the Experimentsmentioning
confidence: 99%
“…The glass transition temperature (Tg) of polymers predicts how heat-induced sterilization causes chemical and structural changes in polymer properties [ 39 ]. A material with Tg close to steam-sterilization temperature can affect the polymeric chain mobility and its dimensional and mechanical characteristics [ 40 ].…”
Section: Discussionmentioning
confidence: 99%