2002
DOI: 10.1016/s0960-1481(01)00057-x
|View full text |Cite
|
Sign up to set email alerts
|

Heat transfer coefficient and friction factor correlations for rectangular solar air heater duct having transverse wedge shaped rib roughness on the absorber plate

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
81
0

Year Published

2013
2013
2024
2024

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 305 publications
(82 citation statements)
references
References 10 publications
1
81
0
Order By: Relevance
“…The nonselective absorber surface exhibited more thermal radiation emission than convective loss, thus making the radiative loss component dominant (Mintsa Do Ango et al [31] and Gao et al [15] ). Bhagoria et al [32] and Gao et al [15] propose the use of rough surfaces to improve the convective heat transfer coefficient. In the natural convection and analytical approach of Gao et al [15] in which a flat absorbing and flat bottom plates were used as the air flow channels, constant values of h rgs , h rpg , and h cpf reported were, respectively, 12.4, 5.9, and 8.8 W m…”
Section: Effect Of Design Decisionsmentioning
confidence: 99%
“…The nonselective absorber surface exhibited more thermal radiation emission than convective loss, thus making the radiative loss component dominant (Mintsa Do Ango et al [31] and Gao et al [15] ). Bhagoria et al [32] and Gao et al [15] propose the use of rough surfaces to improve the convective heat transfer coefficient. In the natural convection and analytical approach of Gao et al [15] in which a flat absorbing and flat bottom plates were used as the air flow channels, constant values of h rgs , h rpg , and h cpf reported were, respectively, 12.4, 5.9, and 8.8 W m…”
Section: Effect Of Design Decisionsmentioning
confidence: 99%
“…Bhagoria,Saini,Solanki [3] performed this experiment to collect heat transfer and friction data for forced convection flow of air in solar air heater rectangular duct with one broad wall roughened by wedge shaped transverse integral ribs. The experiment encompassed the Reynolds number range from 3000 to 18000; relative roughness height 0.015 to 0.033; the relative roughness pitch 60.17Ф-1.0264<p/e<12.12; and rib wedge angle (f) of 8, 10, 12 and 15°.…”
Section: Wedge Shaped Ribsmentioning
confidence: 99%
“…A lot of research has been made in this particular field and many designs have been tested both experimentally and computationally. Bhagoria and Saini [1] conducted experiments on rectangular duct solar air heaters where they added roughness through wedge shaped turbulators having fixed values of relative roughness height and wedge angle. They found that varying the pitch of the roughness affected the heat transfer.…”
Section: Introductionmentioning
confidence: 99%