Abstract:In the present work, enhancement of the thermal performance of a central processor unit (CPU) cooling system through a heat sink subjected to an impinging air jet is realized. The height of the impinging air jet duct, the mode of air flow on the heat sink, air blowing mode and as well as the suction blow mode "pull" and the air jet duct geometry are three important influence parameters on the phenomenon. The results obtained show that a jet height H = 20mm, a convergent duct of H = 40mm in height and a hair d… Show more
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.