2020
DOI: 10.3389/fvets.2020.00428
|View full text |Cite
|
Sign up to set email alerts
|

Heparinized Saline Solution vs. Saline Solution (0.9% Sodium Chloride) for the Maintenance of Dorsal Pedal Arterial Catheter Patency in Dogs Undergoing General Anesthesia: A Pilot Study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
2
1

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(5 citation statements)
references
References 26 publications
0
5
0
Order By: Relevance
“…Lactated Ringer's solution (Lactec; Otsuka Pharmaceutical Factory, Nihon Kohden, Tokyo, Japan) to measure AP (Figure 2). The transducer was placed at the level of the right atrium as a reference point for zero pressure (22,23). Heparinized saline solution (4 IU•mL −1 ) was used to flush the arterial catheter, and infusion was commenced at a rate of 3 mL•h −1 with 300 mm Hg pressure applied to the infuser bag (22,23).…”
Section: Preparationmentioning
confidence: 99%
See 1 more Smart Citation
“…Lactated Ringer's solution (Lactec; Otsuka Pharmaceutical Factory, Nihon Kohden, Tokyo, Japan) to measure AP (Figure 2). The transducer was placed at the level of the right atrium as a reference point for zero pressure (22,23). Heparinized saline solution (4 IU•mL −1 ) was used to flush the arterial catheter, and infusion was commenced at a rate of 3 mL•h −1 with 300 mm Hg pressure applied to the infuser bag (22,23).…”
Section: Preparationmentioning
confidence: 99%
“…The transducer was placed at the level of the right atrium as a reference point for zero pressure (22,23). Heparinized saline solution (4 IU•mL −1 ) was used to flush the arterial catheter, and infusion was commenced at a rate of 3 mL•h −1 with 300 mm Hg pressure applied to the infuser bag (22,23). Surface ECG was recorded to monitor the heart rate (HR).…”
Section: Preparationmentioning
confidence: 99%
“…Four studies (LOE 5, fair) were identified that evaluated the function of arterial catheters in dogs and reported subsequent complications such as thrombosis 308–311 . None of these reports included a relevant control population (dogs without arterial catheters); hence, all 4 studies were considered neutral to the PECO question.…”
Section: Peco Question: Arterial Catheters (Dogs)mentioning
confidence: 99%
“…Four studies (LOE 5, fair) were identified that evaluated the function of arterial catheters in dogs and reported subsequent complications such as thrombosis. [308][309][310][311] None of these reports included a relevant control population (dogs without arterial catheters); hence, all 4 studies were considered neutral to the PECO question. Additionally, the complication defined as 'catheter occlusion' was not characterized in all cases to distinguish potential causes such as intraluminal thrombosis, catheter kinking, arterial spasm or thromboembolism.…”
Section: Evidence Summarymentioning
confidence: 99%
See 1 more Smart Citation