2022
DOI: 10.1002/aoc.6767
|View full text |Cite
|
Sign up to set email alerts
|

Heteronuclear metal–organic framework‐based fluorescent sensor for the detection of tetracycline antibiotics

Abstract: The residues of tetracycline antibiotics (TCs) have caused serious environmental pollution due to the multi‐field application. In order to rapidly detect TCs, there is an urgent need to design new fluorescence sensor. Herein, a heterometallic metal‐organic framework (HNU‐61) is constructed and used as a fluorescence sensor for detecting the TCs. In HNU‐61, both Zn2+ and Li+ ions are assembled into the crystal structure, in which Zn2+ adopts tetrahedral coordination mode, and can be served as the potential coor… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 11 publications
(2 citation statements)
references
References 36 publications
0
2
0
Order By: Relevance
“… Detection method for TCs Detection range (nmol/L) Limit of detection (LOD) (nmol/L) Ref. TC OTC CTC TC OTC CTC CL method 10–2400 10–2800 5–2100 4.0 6.0 2.0 This work HPLC 300–1600 300–1800 300–1700 150 150 150 This work ELISA 0.58–4.5 1.62 7.2 14.4 ( Chen et al, 2015 ) Ratio fluorescence 10–10 4 5.0 ( Zhang et al, 2022 ) MOF-fluorescent 0–2 × 10 4 0–2 × 10 4 0–2 × 10 4 65 390 92 ( Wang et al, 2022 ) Fluorescence 25–1750 9.5 (Y. Wang et ...…”
Section: Resultsmentioning
confidence: 97%
“… Detection method for TCs Detection range (nmol/L) Limit of detection (LOD) (nmol/L) Ref. TC OTC CTC TC OTC CTC CL method 10–2400 10–2800 5–2100 4.0 6.0 2.0 This work HPLC 300–1600 300–1800 300–1700 150 150 150 This work ELISA 0.58–4.5 1.62 7.2 14.4 ( Chen et al, 2015 ) Ratio fluorescence 10–10 4 5.0 ( Zhang et al, 2022 ) MOF-fluorescent 0–2 × 10 4 0–2 × 10 4 0–2 × 10 4 65 390 92 ( Wang et al, 2022 ) Fluorescence 25–1750 9.5 (Y. Wang et ...…”
Section: Resultsmentioning
confidence: 97%
“…[29][30][31][32][33] Due to its benefits of simplicity, high efficiency, fast response, and high selectivity, fluorescence sensing has attracted much attention. [34][35][36][37][38] Benefiting from the strong fluorescence emission and stable structure, the fluorescence detection performance of HNU-82 for antibiotics was also investigated. The fluorescence intensity of HNU-82 has a good quenching effect on nitrofurazone (NZF) and nitrofurantoin (NFT) in aqueous solution with the detection limits of NZF and NFT were 6.60 × 10 −7 mol L −1 and 4.62 × 10 −7 mol L −1 , respectively.…”
Section: Introductionmentioning
confidence: 99%