2016
DOI: 10.1159/000448626
|View full text |Cite
|
Sign up to set email alerts
|

High Diagnostic Value of a New Real-Time Pneumocystis PCR from Bronchoalveolar Lavage in a Real-Life Clinical Setting

Abstract: Background: To diagnose Pneumocystis jirovecii pneumonia (PCP), PCR testing in bronchoalveolar lavage (BAL) fluid has recently become an alternative to immunofluorescence testing (IFT); however, its diagnostic accuracy is less clear. Objective: To analyze the diagnostic value of a new semiquantitative real-time PCR (RT-PCR) in BAL in a real-life clinical setting. Methods: Retrospective analysis of all RT-PCR results [semiquantitative: negative, weakly positive, and strongly positive; measured in cycle threshol… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0
2

Year Published

2017
2017
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 14 publications
(9 citation statements)
references
References 26 publications
0
7
0
2
Order By: Relevance
“…Conventional microbiology testing by cultures is time consuming. DNA‐based testing through polymerase chain reactions (multiplex PCR) may provide a faster alternative and have proven benefits in detecting some pathogens such as Pneumocystis jirovecii . However, data regarding BAL detection of other lung pathogens in LTx recipients are lacking.…”
Section: Introductionmentioning
confidence: 99%
“…Conventional microbiology testing by cultures is time consuming. DNA‐based testing through polymerase chain reactions (multiplex PCR) may provide a faster alternative and have proven benefits in detecting some pathogens such as Pneumocystis jirovecii . However, data regarding BAL detection of other lung pathogens in LTx recipients are lacking.…”
Section: Introductionmentioning
confidence: 99%
“…The less cycle the increasing of CT indicated the more targeted DNA load in the sample. 16 Cycle threshold value positively correlated with the microorganism density in the sample. 17 A cut off CT value of 32 cycle can be applied in differentiating colonization to P. jiroveci infection with sensitivity 72% and specificity 75%.…”
Section: Resultsmentioning
confidence: 93%
“…The P. jiroveci DNA can be detected even after prophylactic therapy but the microscopy examination can be difficult to achieve. 16 …”
Section: Resultsmentioning
confidence: 99%
“…Kantitasyon olanağı sunması nedeniyle kolonizasyon/enfeksiyon ayrımında fikir veriyor olması yöntemin birincil üstünlüğü olarak gösterilmektedir [22][23][24] . Uygulamasının kolay ve hızlı bir yöntem olmasının yanı sıra kapalı sistem olması nedeniyle dışarıdan kontaminasyon riskini en aza indirmesi, yöntemin diğer avantajları olarak öne çıkmaktadır 8,22,23,[25][26][27] .…”
Section: Discussionunclassified