1994
DOI: 10.1088/0031-8949/50/4/003
|View full text |Cite
|
Sign up to set email alerts
|

High-performance x-ray spectroscopic devices for plasma microsources investigations

Abstract: X-ray spectroscopy with high spectral (up to AA/A = lo-*) and spatial resolution (up to 1 pm) is discussed. Devices based on crystals, diffraction and Bragg-Fresnel elements and their applications in Zand X-pinches and laser plasma experiments are described.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
53
0

Year Published

2006
2006
2021
2021

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 189 publications
(53 citation statements)
references
References 8 publications
0
53
0
Order By: Relevance
“…This method allows determining the projectile ion charge and velocity as a function of the ion penetration depth in the stopping medium. The high spectral (l/Dl ¼ 2000-5000) and spatial (30 -70 mm) resolutions were achieved using a spherically bend crystal spectrometer and Kodak X-ray films (Faenov et al, 1994;Rosmej et al, 2002).…”
Section: Experimental Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…This method allows determining the projectile ion charge and velocity as a function of the ion penetration depth in the stopping medium. The high spectral (l/Dl ¼ 2000-5000) and spatial (30 -70 mm) resolutions were achieved using a spherically bend crystal spectrometer and Kodak X-ray films (Faenov et al, 1994;Rosmej et al, 2002).…”
Section: Experimental Methodsmentioning
confidence: 99%
“…During the penetration in a stopping medium, the ion velocity and therefore the Doppler shift are decreasing continuously imaging the deceleration process. A high spectral resolution (l/dl ¼ 3000) of the spherically bend mica spectrometer (Faenov et al, 1994) allows obtaining the ion velocity dependence with the penetration depth using the Doppler line shift with Fig. 1.…”
Section: K-shell Spectra Of Calcium Ions Penetrating Sio 2 Low-densitmentioning
confidence: 99%
“…Meanwhile, the holes in the mirror and focusing lens affect the laser radiation flux density at the center of the focusing area decreasing the intensity to the value about 2 × 10 11 W/cm 2 . The soft X-ray line radiation from the plasma in the direction normal to the target surface was studied with the spherically bent mica crystal spectrograph (Faenov et al, 1994;Skobelev et al, 1995). The curvature radius of a crystal was 150 mm.…”
Section: Experimental Set Upmentioning
confidence: 99%
“…7 The mica crystal ͑2d = 19.94 A͒ plate was bent spherically to a radius of 150 mm and the effective reflecting area was about 10 ϫ 50 mm 2 . The reflected x rays were recorded by using a direct exposure x-ray film ͑DEF-5͒ that has high and stable sensitivity for the 1-10 keV photons.…”
Section: Experiments Setupmentioning
confidence: 99%