2000
DOI: 10.1590/s0104-66322000000200006
|View full text |Cite
|
Sign up to set email alerts
|

High-pressure vapor-liquid equilibrium data for CO2-orange peel oil

Abstract: Recently, there has been a growing interest in fractionating orange peel oil by the use of supercritical carbon dioxide (SCCO2). However, progress in this area has been hindered by the lack of more comprehensive work concerning the phase equilibrium behavior of the SCCO2-orange peel oil system. In this context, the aim of this work is to provide new phase equilibrium data for this system over a wide range of temperatures and pressures, permitting the construction of coexistence PT-xy curves as well as the P-T … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
10
0
2

Year Published

2004
2004
2015
2015

Publication Types

Select...
10

Relationship

3
7

Authors

Journals

citations
Cited by 31 publications
(12 citation statements)
references
References 14 publications
0
10
0
2
Order By: Relevance
“…The experimental apparatus and procedure have been described in detail in a variety of studies [25][26][27][28][29][30][31][32] and were extensively validated [33][34][35][36]. The experimental apparatus was employed to conduct the experiments up to 20.6 MPa and T = 343.15 K. After preliminary tests, the molar ratio of ethanol to CO 2 was kept constant at 1:3 for all experimental measurements, which provided proper visualization of phase transitions and required an adequate time for solubilization.…”
Section: Phase Equilibrium Apparatus and Experimental Proceduresmentioning
confidence: 99%
“…The experimental apparatus and procedure have been described in detail in a variety of studies [25][26][27][28][29][30][31][32] and were extensively validated [33][34][35][36]. The experimental apparatus was employed to conduct the experiments up to 20.6 MPa and T = 343.15 K. After preliminary tests, the molar ratio of ethanol to CO 2 was kept constant at 1:3 for all experimental measurements, which provided proper visualization of phase transitions and required an adequate time for solubilization.…”
Section: Phase Equilibrium Apparatus and Experimental Proceduresmentioning
confidence: 99%
“…The experimental apparatus and procedure have been used in a variety of studies [20][21][22][23][24] and was extensively validated [25,26]. Briefly, the experimental setup consists of a variable-volume view cell with two sapphire windows (one for light input and one for visual observation), an absolute pressure transducer (Smar, model LD 301), a portable programmer (Smar, model HT 201) for pressure acquisition, and a syringe pump (ISCO, model 260D).…”
Section: Phase Equilibrium Apparatus and Proceduresmentioning
confidence: 99%
“…The experimental apparatus and procedure have been used in a variety of studies [18][19][20][21][22][23][24][25] and were extensively validated [26][27][28][29][30].…”
Section: Phase Equilibrium Apparatus and Experimental Proceduresmentioning
confidence: 99%