2022
DOI: 10.1002/mp.15653
|View full text |Cite
|
Sign up to set email alerts
|

High‐resolution and high‐sensitivity PET for quantitative molecular imaging of the monoaminergic nuclei: A GATE simulation study

Abstract: Purpose Quantitative in vivo molecular imaging of fine brain structures requires high‐spatial resolution and high‐sensitivity. Positron emission tomography (PET) is an attractive candidate to introduce molecular imaging into standard clinical care due to its highly targeted and versatile imaging capabilities based on the radiotracer being used. However, PET suffers from relatively poor spatial resolution compared to other clinical imaging modalities, which limits its ability to accurately quantify radiotracer … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
16
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5

Relationship

3
2

Authors

Journals

citations
Cited by 16 publications
(16 citation statements)
references
References 108 publications
0
16
0
Order By: Relevance
“…We performed DOI rebinning in the list-mode to correct for the PE-caused spatial blurring. 34 In specific, for each coincidence event, we drew the LOR between the two photon interaction sites based on the continuous DOI information, and the event was re-assigned to the pair of crystals with their gamma photon entrance surface intersecting the LOR. 34,40 A cylinder phantom with 25.4 cm in diameter and 5 cm in axial, which covered the entire FOV of the prototype, was scanned to obtain the normalization data (∼200 million events).…”
Section: Image Reconstructionmentioning
confidence: 99%
See 4 more Smart Citations
“…We performed DOI rebinning in the list-mode to correct for the PE-caused spatial blurring. 34 In specific, for each coincidence event, we drew the LOR between the two photon interaction sites based on the continuous DOI information, and the event was re-assigned to the pair of crystals with their gamma photon entrance surface intersecting the LOR. 34,40 A cylinder phantom with 25.4 cm in diameter and 5 cm in axial, which covered the entire FOV of the prototype, was scanned to obtain the normalization data (∼200 million events).…”
Section: Image Reconstructionmentioning
confidence: 99%
“…34 In specific, for each coincidence event, we drew the LOR between the two photon interaction sites based on the continuous DOI information, and the event was re-assigned to the pair of crystals with their gamma photon entrance surface intersecting the LOR. 34,40 A cylinder phantom with 25.4 cm in diameter and 5 cm in axial, which covered the entire FOV of the prototype, was scanned to obtain the normalization data (∼200 million events). The DOI rebinning was performed to the normalization data and the rebinned events were sorted into a LOR map that records the number of counts of all the valid LORs.…”
Section: Image Reconstructionmentioning
confidence: 99%
See 3 more Smart Citations