2008
DOI: 10.1016/j.nimb.2008.05.026
|View full text |Cite
|
Sign up to set email alerts
|

High resolution beam line for the SHARAQ spectrometer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
8
0

Year Published

2011
2011
2023
2023

Publication Types

Select...
5
2
1

Relationship

1
7

Authors

Journals

citations
Cited by 19 publications
(8 citation statements)
references
References 5 publications
0
8
0
Order By: Relevance
“…Especially when angular and energy straggling in the target are not a major concern, spectacular results can be achieved, even if in a reduced solid angle and momentum acceptance. Examples are the SPEG spectrometer [40] at GANIL (France), the WS -Grand Raiden [41] at RCNP -Osaka (Japan), and the new BigRIPS -SHARAQ [42] at RIKEN (Japan).…”
Section: The Use Of Correcting Lensesmentioning
confidence: 99%
“…Especially when angular and energy straggling in the target are not a major concern, spectacular results can be achieved, even if in a reduced solid angle and momentum acceptance. Examples are the SPEG spectrometer [40] at GANIL (France), the WS -Grand Raiden [41] at RCNP -Osaka (Japan), and the new BigRIPS -SHARAQ [42] at RIKEN (Japan).…”
Section: The Use Of Correcting Lensesmentioning
confidence: 99%
“…The highresolution beam line was designed to enable a dispersion-matched operation with the SHARAQ spectrometer [2], with which we can cancel effects originating from the beam momentum spread. FH9 have values of dispersion in the range of 1.9-22.6 m. A number placed on each quadrupole multiplet is a serial number of the element.…”
Section: High-resolution Beam Linementioning
confidence: 99%
“…Ten superconducting triplet quadrupole (STQ7-15 and 19) [4] and three normal conducting quadrupole magnets are used to transport the RI beams. In the figure, horizontal beam trajectories in the dispersion matched mode for the x F3 = ±3 mm, θ F3 = ±10 mrad, and δ = ±0.3% are shown, where x F3 , θ F3 , and δ indicate position, angular, and momentum deviations from the central ray at F3 [2].…”
Section: High-resolution Beam Linementioning
confidence: 99%
See 1 more Smart Citation
“…The SHARAQ 1 spectrometer [1,2] and High-Resolution Beamline [3] (HRB), which began operation in March 2009 at the RI beam Factory (RIBF), were constructed for aiming at highresolution spectroscopy with reactions induced by radioactive ions (RI's) at 100A-350A MeV using the missing-mass method and exploring new experimental techniques in the field of nuclear physics. The HRB is located at the downstream of BigRIPS [4], where RI beams are produced by fragmentation and/or fission reactions from a primary nuclear beam such as 238 U.…”
Section: Introductionmentioning
confidence: 99%