2021
DOI: 10.1063/5.0048726
|View full text |Cite
|
Sign up to set email alerts
|

High resolution x-ray emission spectrometer for multiple hard x-ray emission lines: Demonstration for Cu Kα and Kβ emissions

Abstract: We present a compact 3D printed x-ray emission spectrometer based on the von Hamos geometry that represents a significant upgrade to the existing von Hamos geometry-based miniature x-ray emission spectrometer (miniXES) [Mattern et al., Rev. Sci. Instrum. 83(2), 023901 (2012)]. The upgrades include the incorporation of a higher pixel density 500K detector for improved energy resolution and an enlarged sample area to accommodate a wider range of sample formats. The versatile spectrometer houses removable crystal… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
2

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 22 publications
0
2
0
Order By: Relevance
“…A miniature X-ray emission spectrometer (miniXES) was employed to obtain high-resolution spectra within $ 1 eV (Solovyev et al, 2021;Mattern et al, 2012). The miniXES requires a micro-focused incident X-ray beam with a short working distance, flat analyzer crystals arranged on von Hamos geometry, and two-dimensional position-sensitive detector (2D-PSD) to collect energy-resolved fluorescence signal from the sample.…”
Section: Xes Measurement and Experimental Broadening Calculationmentioning
confidence: 99%
See 1 more Smart Citation
“…A miniature X-ray emission spectrometer (miniXES) was employed to obtain high-resolution spectra within $ 1 eV (Solovyev et al, 2021;Mattern et al, 2012). The miniXES requires a micro-focused incident X-ray beam with a short working distance, flat analyzer crystals arranged on von Hamos geometry, and two-dimensional position-sensitive detector (2D-PSD) to collect energy-resolved fluorescence signal from the sample.…”
Section: Xes Measurement and Experimental Broadening Calculationmentioning
confidence: 99%
“…The broadening of the spectrum, half width at halfmaximum (HWHM), due to the 2D-PSD pixel resolution was determined by fitting elastic scattering lines with a Gaussian function. The resolution depends on the pixel size, optical geometry and analyzer (Solovyev et al, 2021). The elastic scatterings were collected during the calibration.…”
Section: Xes Measurement and Experimental Broadening Calculationmentioning
confidence: 99%