2012
DOI: 10.1039/c2cp41520h
|View full text |Cite
|
Sign up to set email alerts
|

High sensitivity and versatility of the DEER experiment on nitroxide radical pairs at Q-band frequencies

Abstract: Measurement of distances with the Double Electron-Electron Resonance (DEER) experiment at X-band frequencies using a pair of nitroxides as spin labels is a popular biophysical tool for studying function-related conformational dynamics of proteins. The technique is intrinsically highly precise and can potentially access the range from 1.5 to 6-10 nm. However, DEER performance drops strongly when relaxation rates of the nitroxide spin labels are high and available material quantities are low, which is usually th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

4
196
0

Year Published

2013
2013
2024
2024

Publication Types

Select...
8
2

Relationship

3
7

Authors

Journals

citations
Cited by 184 publications
(200 citation statements)
references
References 41 publications
4
196
0
Order By: Relevance
“…All experiments were performed on a customized Bruker Elexsys E580 Q-band spectrometer [35] with a previously described extension by a 12 GS/s AWG (Agilent M8190A) [30]. The temperature was 10 K and the repetition rate of the pulse sequences was 342 µs in the case of Gd-ruler 1 3 and 716 µs for all the other Gd-rulers.…”
Section: Epr Experimentsmentioning
confidence: 99%
“…All experiments were performed on a customized Bruker Elexsys E580 Q-band spectrometer [35] with a previously described extension by a 12 GS/s AWG (Agilent M8190A) [30]. The temperature was 10 K and the repetition rate of the pulse sequences was 342 µs in the case of Gd-ruler 1 3 and 716 µs for all the other Gd-rulers.…”
Section: Epr Experimentsmentioning
confidence: 99%
“…For DEER measurements in detergent solution, double cys-mutants of TM287/288 were spin-labeled with MTSL [(1-oxyl-2,2,5,5-tetramethyl-Δ3-pyrroline-3-methyl) methanethiosulfonate] and incubated in the presence or absence of 2.5 mM AMP-PNP and 2.5 mM MgCl 2 at 25°C prior to flash freezing in cold liquid pentane. DEER traces were recorded at Q band with all pulses set to 12 ns and frequency separation of 100 MHz (37). Data analysis and simulation of the MTSL rotamers on the X-ray structures were performed with the softwares DeerAnalysis2013 (38) and MMM2013.2 (19).…”
Section: Methodsmentioning
confidence: 99%
“…X-band measurements were per-formed on a Bruker ElexSys 580 spectrometer equipped with a Bruker split-ring or dielectric resonator (ER 4118X -MS3 or ER 4118 MD5). Q-band measurements were performed on a home-built high power spectrometer [48,49] equipped with a custom resonator for samples with 3 mm outer diameter [50]. The S-band measurements were performed on a home built spectrometer [51].…”
Section: Epr Measurementsmentioning
confidence: 99%