2004
DOI: 10.1016/j.jms.2004.05.020
|View full text |Cite
|
Sign up to set email alerts
|

High sensitivity CW-cavity ring down spectroscopy of water in the region of the 1.5μm atmospheric window

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

11
119
2

Year Published

2007
2007
2021
2021

Publication Types

Select...
4
2
1

Relationship

1
6

Authors

Journals

citations
Cited by 150 publications
(132 citation statements)
references
References 58 publications
(135 reference statements)
11
119
2
Order By: Relevance
“…The residual concentration, which is not due to some prior sample in the cell, has been evaluated from [35] to be about 2.5 Â 10 À4 % of the total sample pressure. Note that these NH 3 lines have also been observed elsewhere in an earlier work [21].…”
supporting
confidence: 82%
See 2 more Smart Citations
“…The residual concentration, which is not due to some prior sample in the cell, has been evaluated from [35] to be about 2.5 Â 10 À4 % of the total sample pressure. Note that these NH 3 lines have also been observed elsewhere in an earlier work [21].…”
supporting
confidence: 82%
“…Among them, 9494 observed lines could be assigned (10,161 assigned transitions, taking into account an overlapping of some of the resulting lines) to the 4 major isotopic water species. A statistic of the lines is given in Table 2 where the number of assignments is compared to the most complete observations in this region [19,21,22] and to the HITRAN database [35]. It is seen that a progress compared to HITRAN has been mainly achieved for H 2 16 O and HDO.…”
Section: Line Identifications Positions and Assignmentsmentioning
confidence: 99%
See 1 more Smart Citation
“…Each of the 200 experimental data points (solid markers) corresponds to the average of 100 ring-down events. Apart from the C 2 H 2 absorption line, peaks of NH 3 (6565.496 cm -1 and 6565.692 cm -1 [32]), CO 2 (6565.509 cm -1 [30]), hydrogen cyanide (HCN) (6565.532 cm -1 [33]) and heavy water (HDO) (6565.799 cm -1 and 6565.754 cm -1 [28]) were identified in this spectral region. Occasionally, a weak H 2 O line at 6565.501 cm -1 [28] was also observed.…”
Section: Resultsmentioning
confidence: 99%
“…The same type of background signal was also described in Ref. [28], where the authors applied mechanical vibrations to the setup to randomize (and average out) the modulation. In a similar approach, we used a ring-type piezo to apply a slow (2 Hz) sine-wave modulation (of about one FSR) to the front mirror of the cavity.…”
Section: Cavity Ring-down Setupmentioning
confidence: 99%