High-speed liquid film sensor for two-phase flows with high spatial resolution based on electrical conductance

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
34
0

Year Published

2011
2011
2016
2016

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 83 publications
(34 citation statements)
references
References 26 publications
0
34
0
Order By: Relevance
“…Field measurements of local film thickness using sets with a large number of flush-mounted conductivity probes were performed by Sekoguchi et al (1985Sekoguchi et al ( , 1997 and, more recently, by Damsohn and Prasser (2009) and Belt et al (2010). The spatial resolution of flush-mounted conductivity probes is limited by film thickness, which is the characteristic being measured; the greater the film thickness, the larger the conductivity probe, and, therefore, the lower the spatial resolution.…”
Section: Introductionmentioning
confidence: 99%
“…Field measurements of local film thickness using sets with a large number of flush-mounted conductivity probes were performed by Sekoguchi et al (1985Sekoguchi et al ( , 1997 and, more recently, by Damsohn and Prasser (2009) and Belt et al (2010). The spatial resolution of flush-mounted conductivity probes is limited by film thickness, which is the characteristic being measured; the greater the film thickness, the larger the conductivity probe, and, therefore, the lower the spatial resolution.…”
Section: Introductionmentioning
confidence: 99%
“…An auto-balancing bridge was used to measure conductance using a resistance in the feedback network in (Damsohn and Prasser, 2009a) and capacitance using a pair resistance-capacitor in the feedback network in (Thiele et al, 2009). …”
Section: Circuitsmentioning
confidence: 99%
“…The conductance sensor system, designed in Swiss Federal Institute of Technology Zurich (ETHZ) (Damsohn and Prasser, 2009a), has 64 x 16 measuring points and measuring area of 128mm x 32mm and a time resolution of 10000fps. The system can measure films between 100µm and 700µm with spatial resolution of 2mm × 2mm.…”
Section: Conductance Systemmentioning
confidence: 99%
“…The characteristic parameters of annular flow include the thickness of the liquid film, wave velocity, wave height, and shear force, and the liquid film thickness is the basic and most important parameter to be measured accurately [2]. There are many methods that have been developed to investigate the liquid film in gas-liquid annular flow.…”
Section: Introductionmentioning