High-Throughput Non-targeted Chemical Structure Identification Using Gas-Phase Infrared Spectra

Abstract: The high-throughput identification of unknown metabolites in biological samples remains challenging. Most current non-targeted metabolomics studies rely on mass spectrometry, followed by computational methods that rank thousands of candidate structures based on how closely their predicted mass spectra match the experimental mass spectrum of an unknown. We reasoned that the infrared (IR) spectra could be used in an analogous manner and could add orthologous structure discrimination; however, this has never been… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
10
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 6 publications
(10 citation statements)
references
References 87 publications
0
10
0
Order By: Relevance
“…This relatively low false negative rate is much better than the nearly 7% false negative rate we found in our earlier work using a molecular mechanics IR prediction method for triaging. 63 Additionally, CSI:FingerID scoring and ranking accuracy were not significantly affected by the size of the candidate list (Figure S3a). This is important since some candidate lists included more than 15,000 candidate structures (Figure S1c).…”
Section: ■ Results and Discussionmentioning
confidence: 96%
See 3 more Smart Citations
“…This relatively low false negative rate is much better than the nearly 7% false negative rate we found in our earlier work using a molecular mechanics IR prediction method for triaging. 63 Additionally, CSI:FingerID scoring and ranking accuracy were not significantly affected by the size of the candidate list (Figure S3a). This is important since some candidate lists included more than 15,000 candidate structures (Figure S1c).…”
Section: ■ Results and Discussionmentioning
confidence: 96%
“…Importantly, the triage cutoff level we selected (≤1000 compounds) resulted in incorrectly eliminating only 3 of 148 (2%) test compounds. This relatively low false negative rate is much better than the nearly 7% false negative rate we found in our earlier work using a molecular mechanics IR prediction method for triaging . Additionally, CSI:FingerID scoring and ranking accuracy were not significantly affected by the size of the candidate list (Figure S3a).…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Using quantum-chemical methods, vibrational spectra can be routinely and accurately calculated (somewhat in contrast to MS/MS spectra). For example, Karunaratne et al pursued identification of neutral gaseous molecules detected with GC-FTIR spectroscopy by employing DFT-calculated reference spectra of compounds extracted from the PubChem database . This approach yields identification rates comparable to those achieved with MS/MS.…”
Section: Introductionmentioning