2019
DOI: 10.1016/j.jcrs.2018.11.015
|View full text |Cite
|
Sign up to set email alerts
|

Higher-order aberration measurements: Comparison between Scheimpflug and dual Scheimpflug–Placido technology in normal eyes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

2
18
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 15 publications
(21 citation statements)
references
References 28 publications
2
18
1
Order By: Relevance
“…Regarding corneal HOAs, previous studies have reported the results of comparing HOAs measured by different devices. Piccinini et al [ 35 ] compared the HOAs using the Pentacam HR and Galilei G4, which were based on a dual Scheimpflug camera with a placido system in 105 eyes of 105 subjects. Total RMS, coma, and trefoil showed significant difference ( p < 0.001) but not in spherical aberration ( p = 0.125).…”
Section: Discussionmentioning
confidence: 99%
“…Regarding corneal HOAs, previous studies have reported the results of comparing HOAs measured by different devices. Piccinini et al [ 35 ] compared the HOAs using the Pentacam HR and Galilei G4, which were based on a dual Scheimpflug camera with a placido system in 105 eyes of 105 subjects. Total RMS, coma, and trefoil showed significant difference ( p < 0.001) but not in spherical aberration ( p = 0.125).…”
Section: Discussionmentioning
confidence: 99%
“…22 Further, in subjects with normal vision, contrast sensitivity was observed to increase when HOA were corrected with adaptive optics, suggesting that this correction may improve spatial vision particularly for larger pupils. 3 In our study, we were able to detect with sufficient statistical power differences of up to 0.1 μm in measurements of RMS HOA. Hence, as long as this value falls within the normal range, we propose that both devices (Anterion and Pentacam HR) could be used interchangeably, especially for the 4 mm optic zone.…”
Section: Discussionmentioning
confidence: 50%
“…Bland-Altman plots were also constructed with SPSS using the LoAs to compare both devices. 19 Sample size calculation was based on recent studies that have analyzed agreement between AS-OCT and Scheimpflug devices, 3,20 and Pentacam corneal aberration measurements. 21 Based on this papers, it was calculated first for three corneal aberration values (RMS HOA: 0.15; Standard deviation (SD): 0.09; Z4_Spherical aberration: 0.1, SD: 0.05; RMS LOA: 0.8; SD: 0.4).…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations