2021
DOI: 10.1016/j.jphotochem.2020.112931
|View full text |Cite
|
Sign up to set email alerts
|

Highly fluorescent nitrogen-doped carbon dots for selective and sensitive detection of Hg2+ and ClO− ions and fluorescent ink

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
6
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 28 publications
(7 citation statements)
references
References 43 publications
1
6
0
Order By: Relevance
“…However, these materials are restricted from use by their toxicity, low sensitivity, and high cost. Therefore, CDs could be an excellent candidate for the determination of Hg 2 + or ClO − ions [ 19 , 20 , 21 , 22 , 23 , 24 ]. For example, fluorescent CDs were synthesized from ascorbic acid and urea and used for the selective determination of Hg 2+ and Cu 2+ ions and bioimaging [ 19 ].…”
Section: Introductionmentioning
confidence: 99%
“…However, these materials are restricted from use by their toxicity, low sensitivity, and high cost. Therefore, CDs could be an excellent candidate for the determination of Hg 2 + or ClO − ions [ 19 , 20 , 21 , 22 , 23 , 24 ]. For example, fluorescent CDs were synthesized from ascorbic acid and urea and used for the selective determination of Hg 2+ and Cu 2+ ions and bioimaging [ 19 ].…”
Section: Introductionmentioning
confidence: 99%
“…The LODs for Pb 2+ and Hg 2+ are 14.32 nM and 56.81 nM, respectively. In addition, the LODs of the proposed technique have lower values as compared to that of other reported methods for the detection of Pb 2+ and Hg 2+ ions [25][26][27][28][44][45][46][47][48][49][50][51][52][53][54] (Table I).…”
Section: Sensitivity Studymentioning
confidence: 84%
“…CDs have been used in different application areas from bioimaging to sensing mainly because of their superior fluorescent properties. CDs are also utilized as fluorescent ink to identify to counterfeit printings, information storage and encryption [65]. In this study, fluorescent ink was prepared by using 15 mL synthesized CDs and 0.5 g polyvinyl alcohol (PVA).…”
Section: Resultsmentioning
confidence: 99%
“…They were mixed by the help of magnetic stirrer for 1 hour. The obtained fluorescent ink was poured into empty fountain pen [65]. As showed in Figure 8(a), there were no significant patterns seen on the filter paper but blue fluorescent pattern was apparent under 365 nm light in Figure 8(b).…”
Section: Resultsmentioning
confidence: 99%