2016
DOI: 10.1016/j.jhazmat.2016.06.051
|View full text |Cite
|
Sign up to set email alerts
|

Highly-sensitive electrocatalytic determination for toxic phenols based on coupled cMWCNT/cyclodextrin edge-functionalized graphene composite

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

3
25
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 47 publications
(28 citation statements)
references
References 60 publications
3
25
0
Order By: Relevance
“…Compared with the detection results of ethanol, toluene, and methanol, the gas sensor based on RGO/SnO 2 composite aerogel has much higher sensitivity to phenol with the LOD down to 5 ppb. In the same year, Gao et al [ 138 ] reported highly sensitive electrocatalytic determination of phenols based on coupled cMWCNT/cyclodextrin edge-functionalized graphene composite. The sensor has excellent performance towards trace detection of three typical phenols (4-aminophenol, 4-AP; 4-chlorophenol, 4-CP; 4-nitrophenol, 4-NP).…”
Section: Phenol Gas Sensorsmentioning
confidence: 99%
“…Compared with the detection results of ethanol, toluene, and methanol, the gas sensor based on RGO/SnO 2 composite aerogel has much higher sensitivity to phenol with the LOD down to 5 ppb. In the same year, Gao et al [ 138 ] reported highly sensitive electrocatalytic determination of phenols based on coupled cMWCNT/cyclodextrin edge-functionalized graphene composite. The sensor has excellent performance towards trace detection of three typical phenols (4-aminophenol, 4-AP; 4-chlorophenol, 4-CP; 4-nitrophenol, 4-NP).…”
Section: Phenol Gas Sensorsmentioning
confidence: 99%
“…The detection limit was determined to be 45 nM for 4-AP on surface of GPE/PtAM. In Table 1, the results of a comparison study of the present work with some different modied electrodes 1,[10][11][12][13][35][36][37] and different chromatography methods, 4,5,9,[38][39][40][41][42] which show acceptable performance according to the tabulated data of this electrode. Furthermore, the interfering effects of other probable coexisting ions such as Ca 2+ , Cl À , Cr 3+ , Cu 2+ , K + , Mg 2+ , Na + , NO 3 À , PO 4 3À , SO 4 2À and Zn 2+ , were investigated and the results showed that the maximum interfering effects for these ions were seen with the determination of 4-AP (5% tolerable molar ratio >100).…”
Section: Linear Range and Detection Limit Oxidation Of 4-apmentioning
confidence: 99%
“…As an outcome, the US Environmental Protection Agency (USEP) and European Union (EU) has recorded 2‐chlorophenol(2‐CP), 2,4‐DCP, 2,4,6‐trichlorophenol (2,4,6‐TCP), and 2,3,4,5,6‐pentachlorophenol (PCP) as pollutants and controlled the greatest allowable convergence of CPs in drinking water at 0.5 ng/mL 34,36 . Recently, numerous traditional methods have been reported for determination of phenol, including spectrofluorimetry, 37 electrochemiluminescence, 38 spectrophotometer, 39 chromatogr‐aphy, 40‐41 electrophoresis, 42 electroanalysis 33,43‐46 . Compared with other methods, an electrochemical sensor is considered one of the best and conservative systems due to its low‐cost, ease of operation, sensitivity, rapidity and simplicity 47‐51 .…”
Section: Introductionmentioning