2014
DOI: 10.1016/j.bios.2013.07.044
|View full text |Cite
|
Sign up to set email alerts
|

Highly sensitive enumeration of circulating tumor cells in lung cancer patients using a size-based filtration microfluidic chip

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
44
0
2

Year Published

2015
2015
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 89 publications
(47 citation statements)
references
References 29 publications
1
44
0
2
Order By: Relevance
“…Because the dissemination of tumor mostly occurs through the blood, circulating tumor cells (CTCs) that have been shed into the vasculature and may be on their way to potential metastatic sites are of obvious interest [54]. CTCs have been shown to be effective biomarkers in [60] and (d) size filtration [61]. (e), (f) Label-free microfluidics isolating CTCs by acoustic waves [62] and optically-induced electrophoretic (ODEP) force [63].…”
Section: Automated Cell Isolation and Deliverymentioning
confidence: 99%
See 2 more Smart Citations
“…Because the dissemination of tumor mostly occurs through the blood, circulating tumor cells (CTCs) that have been shed into the vasculature and may be on their way to potential metastatic sites are of obvious interest [54]. CTCs have been shown to be effective biomarkers in [60] and (d) size filtration [61]. (e), (f) Label-free microfluidics isolating CTCs by acoustic waves [62] and optically-induced electrophoretic (ODEP) force [63].…”
Section: Automated Cell Isolation and Deliverymentioning
confidence: 99%
“…The lysed blood was pumped through the spiral chip using a syringe pump. CTCs were focused near the inner wall due to the combination of the inertial lift force and the Dean drag force at the outlet, while white blood cells and platelets are [60], [61] External excitation force Label-free, fidelity of cell Low throughput, high cost [62], [63] trapped inside the core of the Dean vortex formed closer to the outer wall. CTCs have a diameter that is three to four times as large as the bores of capillaries in distant organs, so they would be expected to become trapped there [54].…”
Section: Automated Cell Isolation and Deliverymentioning
confidence: 99%
See 1 more Smart Citation
“…A size-based filtration microfluidic chip used to detect CTCs in lung cancer patients demonstrated a 73.3% sensitivity and 100% specificity, with a threshold for definition of lung cancer by CTC level set at 5.15 cells per mL (34).…”
Section: Diagnosticmentioning
confidence: 99%
“…This flow rate was still high enough to process the samples in a relatively short time, approximately 10 min per sample, and could potentially be shortened further using highthroughput isolation with parallel processing. In contrast, other alternative devices for cancer cell isolation require several hours [19,43]. Compared to blood samples, clinical urine samples contain fewer background cells and have lower viscosity which may contribute to easier filtration at a relatively high flow rate.…”
Section: Rapid Bc Cell Isolation and Retrievalmentioning
confidence: 99%